Abstract
Rationale: In critically ill patients, a hemoglobin transfusion threshold of <7.0 g/dl compared with <10.0 g/dl improves organ dysfunction. However, it is unclear if transfusion at a hemoglobin of <7.0 g/dl is superior to no transfusion. Objectives: To compare degrees of organ dysfunction between transfusion and no transfusion at a hemoglobin threshold of 20% absolute increase in transfusion rates in all three cohorts. Transfusion was associated with increases in hemoglobin concentration in the subsequent 24–72 hours (MIMIC-IV, 2.4 [95% confidence interval (CI), 1.1 to 3.6] g/dl; eICU, 0.7 [95% CI, 0.3 to 1.2] g/dl; Premier Inc., 1.9 [95% CI, 1.5 to 2.2] g/dl) but not with improvement in organ dysfunction (MIMIC-IV, 4.6 [95% CI, −1.2 to 10] points; eICU, 4.4 [95% CI, 0.9 to 7.8] points; Premier Inc., 1.1 [95% CI, −0.2 to 2.3] points) compared with no transfusion. Conclusions: Transfusion was not associated with improved organ dysfunction compared with no transfusion at a hemoglobin threshold of 7.0 g/dl, suggesting that evaluation of transfusion targets other than a hemoglobin threshold of 7.0 g/dl may be warranted.
Funding Information
  • National Institute of General Medical Sciences (1F32GM133061-01)
  • National Heart, Lung, and Blood Institute (1R01HL151607-01)
  • National Institute of General Medical Sciences (1F32GM133061-01)
  • National Heart, Lung, and Blood Institute (1R01HL151607-01)

This publication has 38 references indexed in Scilit: