Characterization of difference of Gaussian filters in the detection of mammographic regions
Authors:
- David M. CatariousDCDavid M. Catarious
- Alan H. BaydushABAlan H. Baydush
- Carey E. FloydCFCarey E. Floyd
- 17 October 2006
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 33 (11) , 4104-4114
Abstract
In this article, we present a characterization of the effect of difference of Gaussians (DoG) filters in the detection of mammographic regions. DoG filters have been used previously in mammographic mass computer‐aided detection (CAD) systems. As DoG filters are constructed from the subtraction of two bivariate Gaussian distributions, they require the specification of three parameters: the size of the filter template and the standard deviations of the constituent Gaussians. The influence of these three parameters in the detection of mammographic masses has not been characterized. In this work, we aim to determine how the parameters affect (1) the physical descriptors of the detected regions, (2) the true and false positive rates, and (3) the classification performance of the individual descriptors. To this end, 30 DoG filters are created from the combination of three template sizes and four values for each of the Gaussians’ standard deviations. The filters are used to detect regions in a study database of 181 craniocaudal‐view mammograms extracted from the Digital Database for Screening Mammography. To describe the physical characteristics of the identified regions, morphological and textural features are extracted from each of the detected regions. Differences in the mean values of the features caused by altering the DoG parameters are examined through statistical and empirical comparisons. The parameters’ effects on the true and false positive rate are determined by examining the mean malignant sensitivities and false positives per image (FPpI). Finally, the effect on the classification performance is described by examining the variation in FPpI at the point where 81% of the malignant masses in the study database are detected. Overall, the findings of the study indicate that increasing the standard deviations of the Gaussians used to construct a DoG filter results in a dramatic decrease in the number of regions identified at the expense of missing a small number of malignancies. The sharp reduction in the number of identified regions allowed the identification of textural differences between large and small mammographic regions. We find that the classification performances of the features that achieve the lowest average FPpI are influenced by all three of the parameters.Keywords
Funding Information
- USARO (DAMD 17-03-1-0186, DAMD 17-02-1-0367)
This publication has 21 references indexed in Scilit:
- Screening Mammography with Computer-aided Detection: Prospective Study of 12,860 Patients in a Community Breast CenterRadiology, 2001
- Computer-aided diagnosis of breast lesions in medical imagesComputing in Science & Engineering, 2000
- Proposition: All mammograms should be double-readMedical Physics, 1999
- Current Status of the Digital Database for Screening Mammography1998
- Computer-aided breast cancer detection and diagnosis of masses using difference of Gaussians and derivative-based feature saliencyIEEE Transactions on Medical Imaging, 1997
- Computerized detection of masses in digitized mammograms using single-image segmentation and a multilayer topographic feature analysisAcademic Radiology, 1995
- Double reading of mammography screening films-one radiologist or two?Clinical Radiology, 1993
- Classifying mammographic lesions using computerized image analysisIEEE Transactions on Medical Imaging, 1993
- Gains in Accuracy from Replicated Readings of Diagnostic ImagesMedical Decision Making, 1992
- A Mathematical Theory of CommunicationBell System Technical Journal, 1948