Oral Dosage Form Performance Tests: New Dissolution Approaches
- 24 February 2005
- journal article
- comentary
- Published by Springer Nature in Pharmaceutical Research
- Vol. 22 (2) , 182-187
Abstract
The performance test is one of a series of tests that compose the specification in a United States Pharmacopeia (USP) dosage form monograph. For an orally administered, nonsolution dosage form, it is usually satisfied by either a dissolution or disintegration procedure. Dissolution acceptance criteria are usually set in private negotiations between an applicant and a regulatory agency. With information about this private agreement and other information provided in a sponsor’s Request for Revision to USP, the USP’s Council of Experts elaborates a public dosage form monograph. Based on the relationship between the regulatory decisions and the Request for Revision, the USP dissolution procedure links to a regulatory judgment about bioavailability and bioequivalence and, ultimately, to a judgment about safety and efficacy. The current dissolution procedure and acceptance criteria are perceived as having worked well over the years and are generally accepted. This article discusses new approaches that merit consideration. These approaches focus on a) explicit use of hypothesis testing, b) use of parametric tolerance intervals, c) improved ways to set dissolution acceptance criteria, and d) a more flexible protocol to assess conformity. Application of the proposed approaches may better assess, manage, and communicate both manufacturer and consumer risk for dissolution testing.Keywords
This publication has 8 references indexed in Scilit:
- Dissolution: a Continuing PerspectiveDissolution Technologies, 2004
- Content Uniformity and Dose Uniformity: Current Approaches, Statistical Analyses, and Presentation of an Alternative Approach, with Special Reference to Oral Inhalation and Nasal Drug ProductsPharmaceutical Research, 2002
- SAMPLE SIZES FOR BATCH ACCEPTANCE FROM SINGLE- AND MULTISTAGE DESIGNS USING TWO-SIDED NORMAL TOLERANCE INTERVALS WITH SPECIFIED CONTENTJournal of Biopharmaceutical Statistics, 2001
- Dissolution test acceptance sampling plansJournal of Biopharmaceutical Statistics, 1995
- New Methods for One-Sided Tolerance Limits for a One-Way Balanced Random-Effects ANOVA ModelTechnometrics, 1992
- Statistical Intervals1991
- Two-Sided Tolerance Limits for Balanced Random-Effects ANOVA ModelsTechnometrics, 1989
- β-Expectation and β-Content Tolerance Limits for Balanced One-Way ANOVA Random ModelTechnometrics, 1984