Can the Standardized Uptake Values derived from Diagnostic 68Ga-DOTATATE PET/CT Imaging Predict the Radiation Dose delivered to the Metastatic Liver NET Lesions on 177Lu-DOTATATE Peptide Receptor Radionuclide Therapy?

Authors:
  • BSBaljinder Singh
    Baljinder Singh
  • VPVikas Prasad
    Vikas Prasad
  • CSChristiane Schuchardt
    Christiane Schuchardt
  • HKHarshad Kulkarni
    Harshad Kulkarni
  • RBRichard P Baum
    Richard P Baum

Abstract
Introduction: Neuroendocrine neoplasms express somatostatin receptors, enabling the use of somatostatin analogs for molecular imaging, when labeled with the positron-emitter 68Ga for receptor positron emission tomography/computed tomography (PET/CT), and targeted radionuclide therapy, when labeled with beta-emitters, e.g. 90Y and 177Lu. Aim: To investigate if 68Ga-DOTATATE PET-derived standardized uptake values (SUV) correlate with the dose delivered to the liver lesions following 177Lu-DOTATATE radionuclide therapy in patients with neuroendocrine neoplasms. Materials and methods: Twelve adult (8M: 4F; mean age: 55.9 ± 14.5 years; range: 23-78 years) patients with documented neuroendocrine tumor (NET) disease and liver metastases were enrolled in the study. Ten patients were subjected to 68Ga-DOTATATE and one patient each underwent 68Ga-DOTATOC and 68Ga-DOTANOC diagnostic PET/CT imaging. Subsequently, on the basis of positive PET/CT scan findings for the metastatic NET disease, all these patients were subjected to peptide receptor radionuclide therapy (PRRNT) with 177Lu-DOTATATE. The reconstructed PET/CT data was used to calculate the SUVs on the identifiable liver lesions. The scintigraphic data acquired (anterior and posterior whole body images) following therapeutic doses of 177Lu-DOTATATE were subjected to the quantitative analysis (HERMES workstation and OLINDA/EXM software) to calculate the dose delivered to the hepatic lesions. Results: The initial results of this preliminary study indicate poor correlation between SUV and the tumor dose and the linear regression analysis provided R2 values which explained only a small fraction of the total variance. Conclusion: The SUVs derived from 68Ga-DOTA-peptide PET/CT images should be used with caution for the prediction of tumor dose on 177Lu-DOTA-peptide therapy as there are large intra- and interpatient variability. Further studies with large numbers of patients are warranted to establish such a correlation between SUV, tumor dose and the response assessment. How to cite this article: Singh B, Prasad V, Schuchardt C, Kulkarni H, Baum RP. Can the Standardized Uptake Values derived from Diagnostic 68Ga-DOTATATE PET/CT Imaging Predict the Radiation Dose delivered to the Metastatic Liver NET Lesions on 177Lu-DOTATATE Peptide Receptor Radionuclide Therapy? J Postgrad Med Edu Res 2013;47(1):7-13.

This publication has 13 references indexed in Scilit: