Background: Atrioventricular (AV) conduction disturbances requiring permanent pacemaker implantation (PPI) are a common complication after transcatheter aortic valve implantation (TAVI). However, a significant proportion of patients might recover AV conduction at follow-up.Objectives: The aim of our study was to evaluate the recovery of AV conduction by determination through Wenckebach point in patients with PPI and therefore identify patients who could benefit from device reprogramming to avoid unnecessary RV pacing.Methods: We enrolled 43 patients that underwent PM implantation after TAVI at our Department from January 2018 to January 2021. PM interrogation was performed at follow-up and patients with native spontaneous rhythm were further assessed for AV conduction through WP determination.Results: A total of 43 patients requiring a PM represented the final study population, divided in patients with severely impaired AV conduction (no spontaneous valid rhythm or WP < 100; 26) and patients with valid AV conduction (WP ≥ 100; 17). In the first group patients had a significantly higher number of intraprocedural atrioventricular block (AVB) (20 vs. 1, p < 0.005), showed a significant higher implantation depth in LVOT (7.7 ± 2.2 vs. 4.4 ± 1.1, p < 0.05) and lower ΔMSID (−0.28 ± 3 vs. −3.94 ± 2, p < 0.05).Conclusion: AV conduction may recover in a significant proportion of patients. In our study, valve implantation depth in the LVOT and intraprocedural AV block are associated with severely impaired AV conduction. Regular PM interrogation and reprogramming are required to avoid unnecessary permanent right ventricular stimulation in patients with AV conduction recovery.Keywords
This publication has 30 references indexed in Scilit:
- Complications and Health Care Costs Associated With Transvenous Cardiac Pacemakers in a Nationwide AssessmentJACC: Clinical Electrophysiology, 2017
- Pacemaker implantation after TAVI: predictors of AV block persistenceClinical Research in Cardiology, 2017
- Clinical and Echocardiographic Outcomes Following Permanent Pacemaker Implantation After Transcatheter Aortic Valve ReplacementCirculation: Cardiovascular Interventions, 2017
- The normal variants in the left bundle branch systemJournal of Electrocardiology, 2017
- Development and Validation of a Risk Prediction Model for In-Hospital Mortality After Transcatheter Aortic Valve ReplacementJAMA Cardiology, 2016
- Chronic pacing and adverse outcomes after transcatheter aortic valve implantationHeart, 2015
- 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: The Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA)EP Europace, 2013
- Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosisEuropean Heart Journal, 2011
- EuroSCORE as predictor of in-hospital mortality after percutaneous coronary interventionHeart, 2008
- Incidence of atrial fibrillation and thromboembolism in a randomised trial of atrial versus dual chamber pacing in 177 patients with sick sinus syndromeHeart, 2004