Optimized Spectrometers Characterization Procedure for Near Ground Support of ESA FLEX Observations: Part 1 Spectral Calibration and Characterisation
Open Access
- 13 February 2018
- journal article
- research article
- Published by MDPI AG in Remote Sensing
- Vol. 10 (2) , 289
Abstract
The paper presents two procedures for the wavelength calibration, in the oxygen telluric absorption spectral bands (O2-A, λc = 687 nm and O2-B, λc = 760.6 nm), of field fixed-point spectrometers used for reflectance and Sun-induced fluorescence measurements. In the first case, Ne and Ar pen-type spectral lamps were employed, while the second approach is based on a double monochromator setup. The double monochromator system was characterized for the estimation of errors associated with different operating configurations. The proposed methods were applied to three Piccolo Doppio-type systems built around two QE Pros and one USB2 + H16355 Ocean Optics spectrometers. The wavelength calibration errors for all the calibrations performed on the three spectrometers are reported and potential methodological improvements discussed. The suggested calibration methods were validated, as the wavelength corrections obtained by both techniques for the QE Pro designed for fluorescence investigations were similar. However, it is recommended that a neon emission line source, as well as an argon or mercury-argon source be used to have a reference wavelength closer to the O2-B feature. The wavelength calibration can then be optimised as close to the O2-B and O2-A features as possible. The monochromator approach could also be used, but that instrument would need to be fully characterized prior to use, and although it may offer a more accurate calibration, as it could be tuned to emit light at the same wavelengths as the absorption features, it would be more time consuming as it is a scanning approach.Keywords
This publication has 24 references indexed in Scilit:
- Using field spectroscopy to assess the potential of statistical approaches for the retrieval of sun-induced chlorophyll fluorescence from ground and spaceRemote Sensing of Environment, 2013
- Global monitoring of terrestrial chlorophyll fluorescence from moderate spectral resolution near-infrared satellite measurements: methodology, simulations, and application to GOME-2EGUsphere, 2013
- Modeling the impact of spectral sensor configurations on the FLD retrieval accuracy of sun-induced chlorophyll fluorescenceRemote Sensing of Environment, 2011
- Developments for vegetation fluorescence retrieval from spaceborne high‐resolution spectrometry in the O2‐A and O2‐B absorption bandsJournal of Geophysical Research: Atmospheres, 2010
- High resolution field spectroscopy measurements for estimating gross ecosystem production in a rice fieldAgricultural and Forest Meteorology, 2010
- Performance of Spectral Fitting Methods for vegetation fluorescence quantificationRemote Sensing of Environment, 2010
- Remote sensing of solar-induced chlorophyll fluorescence: Review of methods and applicationsRemote Sensing of Environment, 2009
- Chlorophyll Fluorescence: A Probe of Photosynthesis In VivoAnnual Review of Plant Biology, 2008
- Chlorophyll fluorescence—a practical guideJournal of Experimental Botany, 2000
- Spectrometer for fast measurements of in vivo reflectance, absorptance, and fluorescence in the visible and near-infraredRemote Sensing of Environment, 1994