An Integrated Amperometric Biosensor for the Determination of Lactose in Milk and Dairy Products
- 28 May 2010
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 58 (12) , 7141-7148
Abstract
An integrated amperometric biosensor for the determination of lactose is reported. The bioelectrode design is based on the use of a 3-mercaptopropionic acid (MPA) self-assembled monolayer (SAM)-modified gold electrode on which the enzymes β-galactosidase (β-Gal), glucose oxidase (GOD), peroxidase (HRP) and the mediator tetrathiafulvalene (TTF) are coimmobilized by a dialysis membrane. β-Gal catalyzes the hydrolysis of lactose, and the produced glucose is catalytically oxidized to gluconic acid and H2O2, which is reduced in the presence of HRP. This enzyme reaction is mediated by TTF, and the reduction of TTF+ at 0.00 V (vs Ag/AgCl) gives rise to an amperometric signal proportional to the lactose concentration. The biosensor exhibits a good repeatability of the measurement carried out with the same biosensor, a good reproducibility of the responses obtained with different biosensors and a useful lifetime of 28 days. A linear calibration plot was obtained for lactose over the 1.5 × 10−6 to 1.2 × 10−4 M concentration range, with a limit of detection of 4.6 × 10−7 M. The effect of potential interferents (sucrose, lactulose, fructose, arabinose, maltose, galactose, glucose and uric and ascorbic acids) on the biosensor response was evaluated. Furthermore, the bioelectrode exhibits a suitable performance in flow-injection systems in connection with amperometric detection. The developed biosensor was applied to the determination of lactose in milk and other foodstuffs (chocolate, butter, margarine, yogurt, cheese and mayonnaise), and the results obtained were validated by comparison with those provided by using a commercial enzyme test kit.Keywords
This publication has 22 references indexed in Scilit:
- Determination of glucosamine and lactose in milk-based formulae by high-performance liquid chromatographyJournal of Food Composition and Analysis, 2008
- Glucose oxidase-β-galactosidase hybrid biosensor based on glassy carbon electrode modified with mercury for lactose determinationAnalytica Chimica Acta, 2005
- Determination of lactose and d-galactose using thio-NAD+ instead of NAD+International Dairy Journal, 2002
- Amperometric biosensor sensitive to glucose and lactose based on co-immobilization of ferrocene, glucose oxidase, β-galactosidase and mutarotase in β-cyclodextrin polymerAnalytica Chimica Acta, 1998
- Hybrid biosensors to estimate lactose in milkAnalytica Chimica Acta, 1997
- A bio-FET sensor for lactose based on co-immobilized β-galactosidase/glucose dehydrogenaseBiosensors and Bioelectronics, 1994
- Determination of lactose by an enzymatic methodFood Chemistry, 1993
- Flow analysis of lactose and glucose in milk with an improved electrochemical biosensorFood Chemistry, 1990
- Automated determination of fat, crude protein and lactose in ewe milk by infrared spectrometryThe Analyst, 1986
- 630. The determination of lactose in milkJournal of Dairy Research, 1956