Real-time SPARSE-SENSE cine MR imaging in atrial fibrillation: a feasibility study
Authors:
- 13 December 2016
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica
- Vol. 58 (8) , 922-928
Abstract
Cardiac magnetic resonance imaging (MRI) relies on correct ECG-gating, which is hindered in arrhythmia. To examine whether a prototype free-breathing real-time cine sequence using SPARSE-SENSE (SPARSE) improves left ventricular quantification in atrial fibrillation. On a 1.5T MR system left ventricular short-axis stacks were acquired of the SPARSE sequence and of a “reference” steady-state free precession (SSFP) sequence with arrhythmia rejection in 20 patients with atrial fibrillation. Two radiologists independently rated arrhythmia-caused artifact severity in both sequences using a 4-point scale. Coefficients of variation of myocardial signal intensity for both sequences were acquired. Volumetry was performed twice by one reader and once by another reader. Correlation between artifact severity and employed sequence was analyzed by modified Fisher’s exact test. Coefficients of variation and volumetric data were compared by paired t-test and intraclass correlation. Median arrhythmia-caused artifact severity was 2 in both readers for SSFP and 0 (reader 1)/1 (reader 2) for SPARSE, being significantly lower in SPARSE (P < 0.001). Mean coefficient of variance was significantly smaller in SPARSE (0.11 ± 0.04) compared to SSFP (0.22 ± 0.13, P = 0.003), which was interpreted as a hint for fewer artifacts in SPARSE. Only a small difference of 9 ± 15 mL was seen for end-systolic volume (P = 0.019) between sequences, otherwise no significant difference was detected (end-diastolic volume, P = 0.200; stroke volume, P = 0.554; ejection fraction, P = 0.136; myocardial mass, P = 0.353). Intraclass correlation between sequences was good to excellent (range, 0.80–0.97). Real-time MRI with SPARSE data sampling is promising in atrial fibrillation because it reduces arrhythmia-caused artifacts.Keywords
This publication has 15 references indexed in Scilit:
- Real-time SPARSE-SENSE cardiac cine MR imaging: optimization of image reconstruction and sequence validationEuropean Radiology, 2016
- Highly undersampled contrast-enhanced MRA with iterative reconstruction: Integration in a clinical settingMagnetic Resonance in Medicine, 2014
- Evaluation of left ventricular ejection fraction using through-time radial GRAPPAJournal of Cardiovascular Magnetic Resonance, 2014
- Compressed Sensing Single–Breath-Hold CMR for Fast Quantification of LV Function, Volumes, and MassJACC: Cardiovascular Imaging, 2014
- Highly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSEMagnetic Resonance in Medicine, 2012
- Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routineEuropean Radiology, 2010
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- Cardiac MR Imaging: State of the TechnologyRadiology, 2006
- Advanced MR imaging techniques for evaluation of the heart and great vessels.RadioGraphics, 1998
- ALGORITHM 643ACM Transactions on Mathematical Software, 1986