In Vivo Measurements of the Insertion Depth of Cochlear Implant Arrays Using Flat-Panel Volume Computed Tomography
Authors:
- Annett TriegerATAnnett Trieger
- Anja SchulzeASAnja Schulze
- Matthias SchneiderMSMatthias Schneider
- Thomas ZahnertTZThomas Zahnert
- Dirk MürbeDMDirk Mürbe
- 1 January 2011
- journal article
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 32 (1) , 152-157
Abstract
The development of a procedure for the measurement of insertion depth angles of cochlear implant electrode arrays based on flat-panel computed tomography (FPCT) and the application of this technique to in vivo postoperative images. The knowledge of the insertion depth angle of electrode arrays is relevant for the preservation of low-frequency residual hearing and for optimizing speech coding strategies. Until now, the angular position of electrodes was derived from 2-dimensional radiographs. In the present study, 3-dimensional (3D) radiographs provided by FPCT were used to determine the insertion depth according to angular electrode positions with higher accuracy. For this purpose, a new evaluation procedure was designed and applied to radiographs of 15 cochlear implant patients. In contrast to 2-dimensional radiographs, the obtained 3D images show all 3 semicircular channels and therefore allow the determination of a clear reference, which is required for precise insertion angle measurements. Furthermore, the presented FPCT radiographs visualize distinct electrodes. Despite the constant length of the implanted electrode arrays, we have found a considerable variation of measured insertion depth angles, which is consistent with published observations on the variability and the gender dependence of the size of human cochleae. FPCT provides 3D high-resolution radiographic data that enable the determination of the insertion depth angle with high accuracy and, potentially, an angle determination of individual electrodes. Therefore, this low-dose technique is especially appropriate for postoperative investigations after cochlea implantation.Keywords
This publication has 15 references indexed in Scilit:
- Cone Beam Computed Tomography, A Low-Dose Imaging Technique in the Postoperative Assessment of Cochlear ImplantationOtology & Neurotology, 2009
- Imaging of electrode position in relation to electrode functioning after cochlear implantationEuropean Archives of Oto-Rhino-Laryngology, 2009
- Variational Anatomy of the Human CochleaOtology & Neurotology, 2009
- Quality Control After Insertion of the Nucleus Contour and Contour Advance Electrode in AdultsEar & Hearing, 2007
- The Size of the Cochlea and Predictions of Insertion Depth Angles for Cochlear Implant ElectrodesAudiology and Neurotology, 2006
- Acoustic to Electric Pitch Comparisons in Cochlear Implant Subjects with Residual HearingJournal of the Association for Research in Otolaryngology, 2006
- Cochlear Implants: Three-dimensional Localization by Means of Coregistration of CT and Conventional RadiographsRadiology, 2001
- Cochlear view: Postoperative radiography for cochlear implantationAmerican Journal of Otolaryngology, 2000
- Cochlear view: Postoperative radiography for cochlear implantationAmerican Journal of Otolaryngology, 2000
- A cochlear frequency-position function for several species—29 years laterThe Journal of the Acoustical Society of America, 1990