Clinical Implications of TiGRT Algorithm for External Audit in Radiation Oncology
Open Access
- 1 January 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Advanced Biomedical Research
- Vol. 6 (1) , 117
Abstract
Background: Performing audits play an important role in quality assurance program in radiation oncology. Among different algorithms, TiGRT is one of the common application software for dose calculation. This study aimed to clinical implications of TiGRT algorithm to measure dose and compared to calculated dose delivered to the patients for a variety of cases, with and without the presence of inhomogeneities and beam modifiers. Materials and Methods: Nonhomogeneous phantom as quality dose verification phantom, Farmer ionization chambers, and PC-electrometer (Sun Nuclear, USA) as a reference class electrometer was employed throughout the audit in linear accelerators 6 and 18 MV energies (Siemens ONCOR Impression Plus, Germany). Seven test cases were performed using semi CIRS phantom. Results: In homogeneous regions and simple plans for both energies, there was a good agreement between measured and treatment planning system calculated dose. Their relative error was found to be between 0.8% and 3% which is acceptable for audit, but in nonhomogeneous organs, such as lung, a few errors were observed. In complex treatment plans, when wedge or shield in the way of energy is used, the error was in the accepted criteria. In complex beam plans, the difference between measured and calculated dose was found to be 2%–3%. All differences were obtained between 0.4% and 1%. Conclusions: A good consistency was observed for the same type of energy in the homogeneous and nonhomogeneous phantom for the three-dimensional conformal field with a wedge, shield, asymmetric using the TiGRT treatment planning software in studied center. The results revealed that the national status of TPS calculations and dose delivery for 3D conformal radiotherapy was globally within acceptable standards with no major causes for concern.Keywords
This publication has 9 references indexed in Scilit:
- National dosimetric audit network finds discrepancies in AAA lung inhomogeneity correctionsPhysica Medica, 2015
- Dose calculation algorithms in external beam photon radiation therapyInternational Journal of Cancer Therapy and Oncology, 2013
- Treatment planning systems dosimetry auditing project in PortugalPhysica Medica, 2013
- Dosimetric verification of radiotherapy treatment planning systems in Serbia: national auditRadiation Oncology, 2012
- Comparison of Conventional Radiotherapy Techniques with Different Energies in Treating Prostate Cancer, Employing a Designed Pelvis PhantomJournal of Medical Sciences, 2008
- Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situationsPhysics in Medicine & Biology, 2006
- IAEA Technical Reports Series No. 430: Commissioning And Quality Assurance Of Computerized Planning Systems For Radiation Treatment Of CancerMedical Physics, 2006
- A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations*Physics in Medicine & Biology, 2005
- Dose calculations for external photon beams in radiotherapyPhysics in Medicine & Biology, 1999