Hemodynamic Changes by Flow Diverters in Rabbit Aneurysm Models
Authors:
Open Access
- 1 July 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 44 (7) , 1936-1941
Abstract
Background and Purpose—The effect of flow diverter (FD) on hemodynamic changes observed in aneurysms is inevitably affected by the actual structural configuration of deployed FD. We studied the resultant hemodynamic changes after implantation of FDs using computational fluid dynamic simulations based on micro–computed tomography reconstructions in rabbit aneurysm model. Methods—The FDs by micro–computed tomography images and vascular model based on rabbit-specific angiograms in 14 rabbits were reconstructed for computational fluid dynamic studies, and rabbit-specific inlet flow waveforms were used as boundary conditions. The occluded group (n=10) and unoccluded group (n=4) were divided according to the follow-up angiography. Hemodynamic parameters were separately evaluated for significance with respect to FD implantation and healing. Results—The normalized mean wall shear stress of the aneurysm sac and inflow volume were significantly reduced after FD deployment, and the relative residence time was significantly increased after treatment, without significant differences in mean pressure of aneurysm sac. When compared with the unoccluded group, the average relative residence time increment and percentage of inflow volume reduction in occluded group were higher. Additionally, the inlet of stream after FD deployment in the occluded group was more prevalent near the central region of the neck, whereas in the unoccluded group, it was more likely to occur near the proximal part of the neck. Conclusions—This study provided the real structural configurations of fully deployed FDs in vivo. We demonstrated the decrease of wall shear stress, inflow volume, increase of relative residence time, and change of inflow stream induced by FD implantation. The higher relative residence time increment, percentage of inflow volume reduction, and location of stream inlet near the central part of the neck may be closely related to healing.Keywords
This publication has 28 references indexed in Scilit:
- Flow diversion treatment: intra-aneurismal blood flow velocity and WSS reduction are parameters to predict aneurysm thrombosisActa Neurochirurgica, 2012
- Computer modeling of deployment and mechanical expansion of neurovascular flow diverter in patient-specific intracranial aneurysmsJournal of Biomechanics, 2012
- Long-term Clinical and Angiographic Results of Neuroform Stent-Assisted Coil Embolization in Wide-Necked Intracranial AneurysmsNeurosurgery, 2012
- Treatment of intra-cranial aneurysms with the SILK flow diverter: 2 years’ experience with 28 patients at a single centerActa Neurochirurgica, 2012
- Correlation of aneurysm occlusion with actual metal coverage at neck after implantation of flow-diverting stent in rabbit modelsNeuroradiology, 2011
- Computational haemodynamics in two idealised cerebral wide-necked aneurysms after stent placementComputer Methods in Biomechanics and Biomedical Engineering, 2011
- Three-Dimensional Reconstruction of a Cerebral Stent using Micro-CT for Computational SimulationJournal of Intelligent Material Systems and Structures, 2007
- NEUROFORM STENT-ASSISTED COIL EMBOLIZATION OF WIDE-NECK INTRACRANIAL ANEURYSMSNeurosurgery, 2007
- In Vitro Evaluation of Flow Divertors in an Elastase-Induced Saccular Aneurysm Model in RabbitJournal of Biomechanical Engineering, 2007
- Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding techniqueIEEE Transactions on Medical Imaging, 2005