Performance of Continuous Digital Monitoring of Vital Signs with a Wearable Sensor in Acute Hospital Settings
Open Access
Abstract
Background: Continuous vital sign monitoring using wearable sensors has gained traction for the early detection of patient deterioration, particularly with the advent of virtual wards. Objective: The objective was to evaluate the reliability of a wearable sensor for monitoring heart rate (HR), respiratory rate (RR), and temperature in acutely unwell hospital patients and to identify the optimal time window for alert generation. Methods: A prospective cohort study recruited 500 patients in a single hospital. Sensor readings were compared to standard intermittent nurse observations using Bland–Altman plots to assess the limits of agreement. Results: HR demonstrated good agreement with nurse observations (intraclass correlation coefficient [ICC] = 0.66, r = 0.86, p < 0.001), with a mean difference of 3.63 bpm (95% LoA: −10.87 to 18.14 bpm). RR exhibited weaker agreement (ICC = 0.20, r = 0.18, p < 0.001), with a mean difference of −2.72 breaths per minute (95% LoA: −10.91 to 5.47 bpm). Temperature showed poor to fair agreement (ICC = 0.30, r = 0.39, p < 0.001), with a mean difference of −0.57 °C (95% LoA: −1.72 to 0.58 °C). A 10 min averaging window was identified as optimal, balancing data retention and real-time alerting. Conclusions: Wearable sensors demonstrate potential for reliable continuous monitoring of vital signs, supporting their future integration into real-world clinical practice for improved patient safety.Keywords
Funding Information
- National Institute for Health Research (NIHR) Imperial Biomedical Research Centre (BRC)
- National Institute for Health Research (NIHR) Imperial Patient Safety Translational Research Centre
- Royal College of Surgeons England Research Fellowship
- CW plus charity
- NIHR Professorship
This publication has 28 references indexed in Scilit:
- Evidence from ClinicalTrials.gov on the growth of Digital Health Technologies in neurology trialsnpj Digital Medicine, 2023
- Quantifying the use of connected digital products in clinical researchnpj Digital Medicine, 2020
- Wearable sensors to improve detection of patient deteriorationExpert Review of Medical Devices, 2019
- In-hospital cardiac arrest: Is it time for an in-hospital ‘chain of prevention’?Resuscitation, 2010
- “Identifying the hospitalised patient in crisis”—A consensus conference on the afferent limb of Rapid Response SystemsResuscitation, 2010
- A comparison of vital signs charted by nurses with automated acquired values using waveform quality indicesJournal of Clinical Monitoring and Computing, 2009
- A comparison of Antecedents to Cardiac Arrests, Deaths and EMergency Intensive care Admissions in Australia and New Zealand, and the United Kingdom—the ACADEMIA studyResuscitation, 2004
- Vital signs in hospital patients: a systematic reviewInternational Journal of Nursing Studies, 2001
- Can some in-hospital cardio-respiratory arrests be prevented? A prospective surveyResuscitation, 1998
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986