Background: The Intensive Care Unit (ICU) delivers comprehensive care for critically ill patients through continuous 24-hour monitoring. However, medical procedures and the operation of equipment such as ventilators and monitors contribute to elevated noise levels. Prolonged and excessive noise exposure has been shown to cause discomfort, increase stress, and impair patients’ sleep quality. Objective: This study aimed to examine the relationship between noise levels and sleep quality among patients in the ICU of Dr. Soebandi Regional General Hospital, Jember. Methods: A cross-sectional study of 64 adult ICU patients. Noise was recorded using a calibrated A-weighted sound level meter (slow response, Leq) positioned 1.2 m above floor and 2 m from beds, over 24 h; the night-time Leq (22:00–06:00) was paired with each patient’s same-night sleep score. Sleep quality was assessed using the Richards–Campbell Sleep Questionnaire (RCSQ). Results: Mean night-time noise level was 61.9 ± 2.37 dB(A); mean RCSQ 66.5 ± 12.3. Noise correlated negatively with sleep quality (Spearman r = –0.446; 95% CI –0.65 to –0.19; p = 0.001). Conclusion: Higher A-weighted noise was moderately associated with poorer sleep quality, emphasizing the need for targeted noise-reduction strategies in ICU nursing care.