Virtual Unenhanced Images
- 22 June 2021
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 57 (1) , 52-61
Abstract
Objectives: The aim of this study was to compare qualitative and quantitative metrics of virtual unenhanced (VUE) images among dual-source dual-energy computed tomography (dsDECT), rapid kV-switching DECT (rsDECT), and dual-layer detector DECT (dlDECT) using patient and phantom data. Materials and Methods: Forty-four patients with clinical contrast-enhanced abdominal examinations on each of the 3 DECT scanner types and a phantom scanned with the same protocols were included in this retrospective study. Qualitative and quantitative assessment was performed on VUE images. Quantitative evaluation included measurement of attenuation and image noise for various tissues and the phantom. Virtual unenhanced image attenuation and noise were compared between scanner types, and intrapatient interscanner reproducibility of virtual unenhanced image attenuation was calculated as the percentage of measurement pairs with an interscanner difference ≤ 10 HU. Image quality, noise, sharpness, and iodine elimination were assessed qualitatively by 2 radiologists. Results: Significant interscanner differences in VUE attenuation and noise were found in all tissues. dlDECT and rsDECT showed significantly higher VUE attenuation than dsDECT in the aorta, portal vein, and kidneys (P < 0.05). Conversely, VUE attenuation in dsDECT was significantly higher than in dlDECT/rsDECT for subcutaneous and retroperitoneal fat (both P < 0.05). A total of 91.9% (385/419) of measurements were reproducible between rsDECT and dlDECT, 70.9% (297/419) between dsDECT and rsDECT, and 66.8% (280/419) between dsDECT and dlDECT. Virtual unenhanced image attenuation in the contrast media–filled phantom cavity was 12.7 ± 4.7 HU in dlDECT, −5.3 ± 4.2 HU in rsDECT, and −4.0 ± 10.7 HU in dsDECT with significant differences between dlDECT and rsDECT/dsDECT, respectively (P < 0.05), between which attenuation was comparable in the unenhanced extraluminal phantom component (P = 0.11–0.62). Qualitatively, dsDECT yielded best iodine elimination, whereas sharpness, image noise, and overall image quality were rated higher in dlDECT and rsDECT. Conclusions: There are significant interscanner differences in the attenuation measurements and qualitative assessment of VUE images, which should be acknowledged when using these images in patients that are being scanned on different DECT scanner types during imaging follow-up.Keywords
This publication has 26 references indexed in Scilit:
- Characterization of Adrenal Nodules With Dual-Energy CT: Can Virtual Unenhanced Attenuation Values Replace True Unenhanced Attenuation Values?American Journal of Roentgenology, 2012
- Virtual non-contrast in second-generation, dual-energy computed tomography: Reliability of attenuation valuesEuropean Journal of Radiology, 2012
- Dual-Energy CT for Characterization of the Incidental Adrenal Mass: Preliminary ObservationsAmerican Journal of Roentgenology, 2012
- Dual-Energy (Spectral) CT: Applications in Abdominal ImagingRadioGraphics, 2011
- Dual-Energy CT for Detection of Endoleaks After Endovascular Abdominal Aneurysm Repair: Usefulness of Colored Iodine OverlayAmerican Journal of Roentgenology, 2011
- Single-Phase Dual-Energy CT Allows for Characterization of Renal Masses as Benign or MalignantInvestigative Radiology, 2010
- Adrenal ImagingAmerican Journal of Roentgenology, 2010
- Dual-Energy CT in Patients Suspected of Having Renal Masses: Can Virtual Nonenhanced Images Replace True Nonenhanced Images?Radiology, 2009
- The Incidentally Discovered Adrenal MassNew England Journal of Medicine, 2007
- CT Density Measurements for Characterization of Adrenal Tumors Ex Vivo: Variability Among Three CT ScannersAmerican Journal of Roentgenology, 2004