Performance of an improperly sized and stretched-out loose-fitting powered air-purifying respirator: Manikin-based study
- 25 January 2016
- journal article
- research article
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 13 (3) , 169-176
Abstract
The objective of this study was to investigate the protection level offered by a Powered Air-Purifying Respirator (PAPR) equipped with an improperly sized or stretched-out loose-fitting facepiece using constant and cyclic flow conditions. Improperly sized PAPR facepieces of two models as well as a stretched-out facepiece were tested. These facepieces were examined in two versions: with and without exhaust holes. Loose-fitting facepieces (size “large”) were donned on a small manikin headform and challenged with sodium chloride (NaCl) aerosol particles in an exposure chamber. Four cyclic flows with mean inspiratory flows (MIFs) of 30, 55, 85, and 135 L/min were applied using an electromechanical Breathing Recording and Simulation System (BRSS). The manikin Fit Factor (mFF) was determined as the ratio of aerosol concentrations outside (Cout) to inside (Cin) of the facepiece, measured with a P-Trak condensation particle counter (CPC). Results showed that the mFF decreased exponentially with increasing MIF. The mFF values of the stretched-out facepiece were significantly lower than those obtained for the undamaged ones. Facepiece type and MIF were found to significantly affect the performance of the loose-fitting PAPR. The effect of the exhaust holes was less pronounced and depended on the facepiece type. It was concluded that an improperly sized facepiece might potentially offer relatively low protection (mFF < 250) at high to strenuous workloads. The testing was also performed at a constant inhalation flow to explore the mechanism of the particle-facepiece interaction. Results obtained with cyclic flow pattern were consistent with the data generated when testing the loose-fitting PAPR under constant flow conditions. The time-weighted average values of mFF calculated from the measurements conducted under the constant flow regime were capable of predicting the protection under cyclic flow regime. The findings suggest that program administrators need to equip employees with properly sized facepieces and remove stretched-out ones from workplace. Manufacturers should emphasize the importance of proper sizing with their user instructions.Keywords
This publication has 11 references indexed in Scilit:
- Effects of Breathing Frequency and Flow Rate on the Total Inward Leakage of an Elastomeric Half-Mask Donned on an Advanced Manikin HeadformAnnals of Work Exposures and Health, 2013
- Laboratory Evaluation of the Particle Size Effect on the Performance of an Elastomeric Half-mask Respirator against Ultrafine Combustion ParticlesAnnals of Occupational Hygiene, 2013
- Effect of Particle Size on Respiratory Protection Provided by Two Types of N95 Respirators Used in Agricultural SettingsJournal of Occupational and Environmental Hygiene, 2010
- Effect of Exhaled Moisture on Breathing Resistance of N95 Filtering Facepiece RespiratorsAnnals of Occupational Hygiene, 2010
- Health care workers' views about respirator use and features that should be included in the next generation of respiratorsAmerican Journal of Infection Control, 2010
- Performance of an N95 Filtering Facepiece Particulate Respirator and a Surgical Mask During Human Breathing: Two Pathways for Particle PenetrationJournal of Occupational and Environmental Hygiene, 2009
- Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic FlowAnnals of Occupational Hygiene, 2009
- Human Subject Testing of Leakage in a Loose-Fitting PAPRJournal of Occupational and Environmental Hygiene, 2008
- Evaluation of the rationale for concurrent use of N95 filtering facepiece respirators with loose-fitting powered air-purifying respirators during aerosol-generating medical proceduresAmerican Journal of Infection Control, 2008
- Simulated Workplace Protection Factor Study of Powered Air-Purifying and Supplied Air RespiratorsAIHA Journal, 2001