The Biomechanical Analysis of Relative Position Between Implant and Alveolar Bone: Finite Element Method
Authors:
- 1 March 2011
- journal article
- translational periodontology
- Published by Wiley in Journal of Periodontology
- Vol. 82 (3) , 489-496
Abstract
Background: The purpose of this study is to analyze biomechanical interactions in the alveolar bone surrounding implants with smaller‐diameter abutments by changing position of the fixture–abutment interface, loading direction, and thickness of cortical bone using the finite element method.Methods: Twenty different finite element models including four types of cortical bone thickness (0.5, 1, 1.5, and 2 mm) and five implant positions relative to bone crest (subcrestal 1, implant shoulder 1 mm below bone crest; subcrestal 0.5, implant shoulder 0.5 mm below bone crest; at crestal implant shoulder even with bone crest; supracrestal 0.5, implant shoulder 0.5 mm above bone crest; and supracrestal 1, implant shoulder 1 mm above bone crest) were analyzed. All models were simulated under two different loading angles (0 and 45 degrees) relative to the long axis of the implant, respectively. The three factors of implant position, loading type, and thickness of cortical bone were computed for all models.Results: The results revealed that loading type and implant position were the main factors affecting the stress distribution in bone. The stress values of implants in the supracrestal 1 position were higher than all other implant positions. Additionally, compared with models under axial load, the stress values of models under off‐axis load increased significantly.Conclusions: Both loading type and implant position were crucial for stress distribution in bone. The supracrestal 1 implant position may not be ideal to avoid overloading the alveolar bone surrounding implants.Keywords
This publication has 25 references indexed in Scilit:
- Evaluation of Stress Induced by Implant Type, Number of Splinted Teeth, and Variations in Periodontal Support in Tooth‐Implant–Supported Fixed Partial Dentures: A Non‐Linear Finite Element AnalysisJournal of Periodontology, 2010
- Bone Response to Loaded Implants With Non‐Matching Implant‐Abutment Diameters in the Canine MandibleJournal of Periodontology, 2009
- Stress Analysis of Different Angulations of Implant Installation: The Finite Element MethodThe Kaohsiung Journal of Medical Sciences, 2008
- The Influence of Non‐Matching Implant and Abutment Diameters on Radiographic Crestal Bone Levels in DogsJournal of Periodontology, 2008
- Biomechanical interactions in tooth–implant‐supported fixed partial dentures with variations in the number of splinted teeth and connector type: a finite element analysisClinical Oral Implants Research, 2007
- Biomechanical analysis on platform switching: is there any biomechanical rationale?Clinical Oral Implants Research, 2007
- Role of the Microgap Between Implant and Abutment: A Retrospective Histologic Evaluation in MonkeysJournal of Periodontology, 2003
- Biologic Width around one‐ and two‐piece titanium implantsClinical Oral Implants Research, 2001
- Influence of the Size of the Microgap on Crestal Bone Changes Around Titanium Implants. A Histometric Evaluation of Unloaded Non‐Submerged Implants in the Canine MandibleJournal of Periodontology, 2001
- Surgical procedures in partially edentulous patients with ITI implants NoteClinical Oral Implants Research, 2000