Electronic pill-boxes in the evaluation of antihypertensive treatment compliance: comparison of once daily versus twice daily regimen
Authors:
- N. GenesNGN. Genes
- 1 February 2000
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in American Journal of Hypertension
- Vol. 13 (2) , 184-190
Abstract
The objective was to compare the compliance of hypertensive patients treated with captopril twice daily or trandolapril once daily. After a 2-week placebo period, hypertensive patients (diastolic BP 95-115 mm Hg) were randomly allocated to trandolapril 2 mg once daily or to captopril 25 mg twice daily for 6 months. Trandolapril and captopril were packed in electronic pill-boxes equipped with a microprocessor that recorded date and time of each opening (MEMS). Patients' compliance was assessed both by standard pill-count and by electronic monitoring. Blood pressure was measured using a validated semi-automatic device at the end of the placebo period and of the treatment period. One hundred sixty-two patients entered the study. Compliance data were evaluable for 133 patients (62 in the captopril group and 71 in the trandolapril group). Treatment groups were comparable at baseline except for age (P = .046). Using electronic pill-box, overall compliance was 98.9% in the trandolapril group and 97.5% in the captopril group (P = .002). The percentage of missed doses was 2.6% in the trandolapril group and 3.3% in the captopril group (P = .06). The percentage of delayed doses was 1.8% in the trandolapril group and 11.7% in the captopril group (P = .0001). The percentage of correct dosing periods, ie, a period with only one correct recorded opening, was 94.0% in the trandolapril group and 78.1% in the captopril group (P = .0001). Results were unchanged when adjusted for age. At the end of the study, 41% of patients in the trandolapril group and 27% in the captopril group (NS) had their blood pressure normalized (systolic BP <140 and diastolic BP <90 mm Hg). In this 6-month study, the electronic pill-box allowed refined analysis of compliance of hypertensive patients. Patients' compliance with once daily trandolapril was higher than with twice daily captopril. The between-group difference is mainly explained by an increase in delayed doses in the twice daily group.Keywords
This publication has 22 references indexed in Scilit:
- Use of electronic pill boxes to assess risk of poor treatment compliance Results of a large-scale trialAmerican Journal of Hypertension, 1999
- Therapeutic implications of drug 'holidays'European Heart Journal, 1996
- Use of a Microprocessor-Equipped Tablet Box in Monitoring Compliance with Antihypertensive TreatmentJournal of Cardiovascular Pharmacology, 1992
- Dynamics of drug regimen compliance ? its assessment by microprocessor-based monitoringEuropean Journal of Clinical Pharmacology, 1990
- The Relative Risk of Incident Coronary Heart Disease Associated With Recently Stopping the Use of β-BlockersJAMA, 1990
- Time to stop counting the tablets?Clinical Pharmacology & Therapeutics, 1989
- Beta-adrenergic blocker withdrawal syndromes in hypertension and other cardiovascular diseasesAmerican Heart Journal, 1988
- Pill Count Measures of Compliance in a Drug Trial: Variability and SuitabilityAmerican Journal of Hypertension, 1988
- Comparison of withdrawal phenomena after propranolol, metoprolol, and pindololAmerican Heart Journal, 1982
- RANDOMISED CLINICAL TRIAL OF STRATEGIES FOR IMPROVING MEDICATION COMPLIANCE IN PRIMARY HYPERTENSIONThe Lancet, 1975