Sampling and simultaneous determination of volatile per- and polyfluoroalkyl substances in wastewater treatment plant air and water
Open Access
- 25 November 2016
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 409 (5) , 1395-1404
Abstract
Volatile per- and polyfluoroalkyl substances (PFASs) are often used as precursors in the synthesis of nonvolatile PFASs. The volatile PFASs, which include the perfluoroalkyl iodides (PFAIs), fluorotelomer iodides (FTIs), fluorotelomer alcohols (FTOHs), fluorotelomer olefins (FTOs), fluorotelomer acrylates (FTACs), and fluorotelomer methacrylates (FTMACs), are often produced starting from the telomerization process. These volatile compounds can be present in the air and water environment and can be transformed into highly persistent perfluoroalkyl carboxylic acids. With the exception of FTOHs, which are well studied, the determination of other volatile PFASs is also of prime importance in studying the sources and fate of PFASs. In this study, a method was developed to determine representative precursor compounds that included PFAIs, FTIs, FTOs, FTACs, and FTMACs in wastewater treatment plant (WWTP) air and water samples. The sampling and sample preparation step involved the use of solid-phase extraction (SPE) cartridges with HLB™ material to enrich the analyte. Gas chromatography with mass spectrometry was employed for the detection and quantification of the analytes. Method validation results showed high linearity and sensitivity in the positive electron ionization-selected ion monitoring mode (+EI-SIM). The absolute instrumental limits of detection were in the range of 0.5 to 2 pg. The method detection limit (MDL) in air was 1 ng/m3 with the exception of the FTACs which could be only be detected at concentrations higher than 40 ng/m3. The MDL in water was 10 ng/L. Direct spiking of the cartridges and analyte introduction by volatilization from the glass surface onto the SPE material had recoveries between 86 and 100%. The volatile PFASs were shown to readily partition into the air rather than into water. Consequently, large losses in the amount of PFASs were observed when these were spiked into the water. Wastewater treatment plant air and water samples were passed through HLB™ solid-phase materials. The eluates were injected onto a GC-MS system to simultaneously determine the volatile PFASs.Keywords
Funding Information
- Umwelt Bundesamt, Germany ((EKZ) 3712 65 415/01)
This publication has 15 references indexed in Scilit:
- Microbial transformation of 8:2 fluorotelomer acrylate and methacrylate in aerobic soilsChemosphere, 2015
- Perfluoroalkyl and polyfluoroalkyl substances in the environment: Terminology, classification, and originsIntegrated Environmental Assessment and Management, 2011
- Perfluorinated Compounds in the Asian AtmosphereEnvironmental Science & Technology, 2011
- Fluorotelomer ethoxylates: Sources of highly fluorinated environmental contaminants part I: BiotransformationChemosphere, 2010
- Biodegradation of Fluorinated Alkyl Substances2010
- Atmospheric Perfluorinated Acid Precursors: Chemistry, Occurrence, and Impacts2010
- Biodegradation of Perfluorinated Compounds2008
- Perfluoroalkyl Acids: A Review of Monitoring and Toxicological FindingsToxicological Sciences, 2007
- Analysis of per- and polyfluorinated alkyl substances in air samples from Northwest EuropeJournal of Environmental Monitoring, 2007
- Significant Residual Fluorinated Alcohols Present in Various Fluorinated MaterialsEnvironmental Science & Technology, 2006