HPLC Quantitation Of Fenitrothion and 3-Methyl-4-Nitrophenol in Biological Fluids After Prepacked Cartridge Extraction and Its Application to a Poisoning Case

Authors:

Abstract
We describe here the simultaneous determination of fenitrothion and its metabolite, 3-methyl-4-nitrophenol (MNP), in biological fluids by HPLC after SepPakC18 cartridge extraction and its application to a human poisoning case. One ml of serum or urine mixed with an equal volume of 0.1 N HCl was applied to the SepPakC18 cartridge, which was preactivated using methanol (5 ml), hexane/isopropanol (9/1 v/v, 10 ml), methanol (5 ml) and distilled water (5 ml). After washing by 0.1N HCl(5 ml), the eluate with 5 ml of hexane/isopropanol (9/1 v/v) was concentrated, and the residue was dissolved in 100 μl of methanol containing methaqualone (internal standard, 30 μg/ml). A 20 μ of the aliquot was injected into the HPLC. Recovery yields of fenitrothion and MNP from serum and urine ranged from 78.5–93.3%. Linear calibration curves for fenitrothion and MNP were in the range 0.1 – 10 μg/ml. In a human poisoning case at 18.5 hrs after ingestion of Sumithion, concentrations of fenitrothion and MNP in serum were 11.8 and 3.9 μg/ml and those in urine were less than 0.01 μg/ml and 2.8 μg/ml, respectively.