Electroanatomic Mapping and Radiofrequency Ablation of Porcine Left Atria and Atrioventricular Nodes Using Magnetic Resonance Catheter Tracking
Authors:
- Ehud J. SchmidtESEhud J. Schmidt
- Richard P. MallozziRMRichard P. Mallozzi
- Aravinda ThiagalingamATAravinda Thiagalingam
- Godtfred HolmvangGHGodtfred Holmvang
- Andre D'AVilaADAndre D'AVila
- Renee GuhdeRGRenee Guhde
- Robert DarrowRDRobert Darrow
- Glenn S. SlavinGSGlenn S. Slavin
- Maggie M. FungMFMaggie M. Fung
- Jeremy DandoJDJeremy Dando
- Lori FoleyLFLori Foley
- Charles L. DumoulinCDCharles L. Dumoulin
- 1 December 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 2 (6) , 695-704
Abstract
Background— The MRI-compatible electrophysiology system previously used for MR-guided left ventricular electroanatomic mapping was enhanced with improved MR tracking, an MR-compatible radiofrequency ablation system and higher-resolution imaging sequences to enable mapping, ablation, and ablation monitoring in smaller cardiac structures. MR-tracked navigation was performed to the left atrium (LA) and atrioventricular (AV) node, followed by LA electroanatomic mapping and radiofrequency ablation of the pulmonary veins (PVs) and AV node. Methods and Results— One ventricular ablation, 7 PV ablations, 3 LA mappings, and 3 AV node ablations were conducted. Three MRI-compatible devices (ablation/mapping catheter, torqueable sheath, stimulation/pacing catheter) were used, each with 4 to 5 tracking microcoils. Transseptal puncture was performed under x-ray, with all other procedural steps performed in the MRI. Preacquired MRI roadmaps served for real-time catheter navigation. Simultaneous tracking of 3 devices was performed at 13 frames per second. LA mapping and PV radiofrequency ablation were performed using tracked ablation catheters and sheaths. Ablation points were registered and verified after ablation using 3D myocardial delayed enhancement and postmortem gross tissue examination. Complete LA electroanatomic mapping was achieved in 3 of 3 pigs, Right inferior PV circumferential ablation was achieved in 3 of 7 pigs, with incomplete isolation caused by limited catheter deflection. During AV node ablation, ventricular pacing was performed, 3 devices were simultaneously tracked, and intracardiac ECGs were displayed. 3D myocardial delayed enhancement visualized node injury 2 minutes after ablation. AV node block succeeded in 2 of 3 pigs, with 1 temporary block. Conclusions— LA mapping, PV radiofrequency ablation, and AV node ablation were demonstrated under MRI guidance. Intraprocedural 3D myocardial delayed enhancement assessed lesion positional accuracy and dimensions.Keywords
This publication has 24 references indexed in Scilit:
- Left atrial function and scar after catheter ablation of atrial fibrillationHeart Rhythm, 2008
- Arrhythmia Recurrence After Atrial Fibrillation Ablation: Can Magnetic Resonance Imaging Identify Gaps in Atrial Ablation Lines?Journal of Cardiovascular Electrophysiology, 2007
- Magnetic Resonance–Based Anatomical Analysis of Scar-Related Ventricular TachycardiaCirculation Research, 2007
- Magnetic Resonance Imaging and radiofrequency ablationsHerzschrittmachertherapie + Elektrophysiologie, 2007
- Detection of Pulmonary Vein and Left Atrial Scar after Catheter Ablation with Three-dimensional Navigator-gated Delayed Enhancement MR Imaging: Initial Experience1Radiology, 2007
- Characterization of acute and subacute radiofrequency ablation lesions with nonenhanced magnetic resonance imagingHeart Rhythm, 2007
- Integration of Cardiac CT/MR Imaging with Three‐Dimensional Electroanatomical Mapping to Guide Catheter Manipulation in the Left Atrium: Implications for Catheter Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2006
- Initial Experience in the Use of Integrated Electroanatomic Mapping with Three‐Dimensional MR/CT Images to Guide Catheter Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2006
- Characterization of Radiofrequency Ablation Lesions With Gadolinium-Enhanced Cardiovascular Magnetic Resonance ImagingJACC, 2006
- Stereotactic catheter navigation using magnetic resonance image integration in the human heartHeart Rhythm, 2005