Home blood pressure self-monitoring: diagnostic performance in white-coat hypertension
Authors:
- Joan BayóJBJoan Bayó
- Francesc Xavier CosFCFrancesc Xavier Cos
- Carme RocaCRCarme Roca
- Antoni DalfóADAntoni Dalfó
- Maria Montserrat Martín-BaraneraMMMaria Montserrat Martín-Baranera
- Botey AlbertBABotey Albert
- 1 April 2006
- journal article
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 11 (2) , 47-52
Abstract
Objective To determine the diagnostic performance of home blood pressure self-monitoring in white-coat hypertension using a 3-day reading program. Material and methods One hundred and ninety nontreated patients recently diagnosed with mild–moderate hypertension, selected consecutively at four primary healthcare centers in the city of Barcelona, were included. Each patient underwent morning and night home blood pressure self-monitoring with readings in triplicate for three consecutive days, followed by 24-h ambulatory blood pressure monitoring. The normality cut-off point value for home blood pressure self-monitoring and daytime ambulatory blood pressure monitoring was 135/85 mmHg. Results Sixty-three patients were diagnosed with white-coat hypertension with home blood pressure self-monitoring (34.8%; 95% confidence interval: 27.9–42.2) and 74 with ambulatory blood pressure monitoring (41.6%; 95% confidence interval: 33.7–48.4). No statistically significant differences were observed between home blood pressure self-monitoring values and those of diurnal ambulatory blood pressure monitoring [137.4 (14.3)/82.1 (8.3) mmHg vs. 134.8 (11.3)/81.3 (9.5) mmHg]. Home blood pressure self-monitoring diagnostic performance parameters were sensitivity 50.0% (95% confidence interval: 38.3–61.7), specificity 75.7% (95% confidence interval: 66.3–83.2), positive and negative predictive values 58.7% (95% confidence interval: 45.6–70.8) and 68.6% (95% confidence interval: 59.4–76.7), respectively, and positive and negative probability coefficients 2.05 and 0.66, respectively. Analysis of different normality cut-off points using a receiver operating characteristic curve failed to produce significant improvement in the diagnostic performance of home blood pressure self-monitoring. Conclusions The diagnostic accuracy of a 3-day home blood pressure self-monitoring reading program in white-coat hypertension was poor. Ambulatory blood pressure monitoring continues to be the test of choice for this indication.Keywords
This publication has 20 references indexed in Scilit:
- Efectividad de la automedida de la presión arterial en el diagnóstico de la hipertensión clínica aislada. Justificación y diseño del estudioAtencion Primaria, 2005
- Diagnostic value of strategy for the detection of white coat hypertension based on ambulatory and home blood pressure monitoringJournal of Human Hypertension, 2004
- The Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood PressureThe JNC 7 ReportJAMA, 2003
- Self measured and ambulatory blood pressure in assessing the ‘white-coat’ phenomenonJournal Of Hypertension, 2003
- When can the practicing physician suspect white coat hypertension? Statement from the Working Group on Blood Pressure Monitoring of the European Society of HypertensionAmerican Journal of Hypertension, 2003
- Blood pressure measurementBMJ, 2001
- Guidelines for the use of self-blood pressure monitoringJournal Of Hypertension, 2000
- Frequency and determinants of white coat hypertension in mild to moderate hypertension A primary care-based studyAmerican Journal of Hypertension, 1999
- Self-monitoring of blood pressure at homeJournal Of Hypertension, 1998
- For how many days should blood pressure be measured at home in older patients before steady levels are obtained?Journal of Human Hypertension, 1997