Reduction of Starting Current in Large Induction Motors
Open Access
Abstract
Large induction motors can have a high inrush and run-up current during starting, often up to ten times the rated current. In weak supplies, this could be a problem, causing system stability issues and the voltage to dip below acceptable levels. In islanded systems, the capacity could be pulled below its maximum. There are several different starting methods possible, but they are often only suitable for smaller machines. One method not investigated is the use of parallel capacitor compensation during the starting because large induction motors are very inductive during the starting sequence, so that supplying reactive power may be more effective than supplying energy. This paper first investigates several different induction motors with increasing size and assesses their compensation requirements in terms of the reactive power requirement during starting. It is shown that they do generally become more inductive as they increase in size. It is illustrated, using simulations, that using parallel capacitors during starting can significantly reduce the starting current. The concept is tested using a small experimental motor. Series inductors are added to the motor to make it more inductive and look more like a larger machine. The experimental results confirm that the method works. It is also found that the parallel capacitors require series filters to prevent harmonic current, and these can be realized using inductors in series with the compensation capacitors. Point-on switching using solid-state relays was tested, and these can reduce the transient switch-on current over the first voltage cycle.Keywords
Funding Information
- NRF BRICS (116023)
This publication has 32 references indexed in Scilit:
- Soft Start and Voltage Control of Induction Motors Using Floating Capacitor H-Bridge ConvertersIEEE Transactions on Industry Applications, 2016
- A Multisliced Finite-Element Model for Induction Machines Incorporating Interbar CurrentIEEE Transactions on Industry Applications, 2009
- Starting high-inertia loadsIEEE Transactions on Industry Applications, 2001
- Steady-state, lumped-parameter model for capacitor-run, single-phase induction motorsIEEE Transactions on Industry Applications, 1996
- Effects of harmonics on equipmentIEEE Transactions on Power Delivery, 1993
- Minimal transient switching of capacitorsIEEE Transactions on Power Delivery, 1993
- Excitation of isolated three-phase induction generator by a single capacitorIEE Proceedings B Electric Power Applications, 1993
- Harmonics in power systemsPower Engineering Journal, 1989
- Prolonged inrush currents with parallel transformers affect differential relayingElectrical Engineering, 1941
- Transformer current and power inrushes under loadElectrical Engineering, 1937