Initial experience, safety, and feasibility using remote access or onsite technical support for complex ablation procedures: results of the REMOTE study
Open Access
- 19 February 2024
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 5 (3) , 356-362
Abstract
Electroanatomical mapping (EAM) systems are essential for the treatment of cardiac arrhythmias. The EAM system is usually operated by qualified staff or field technical engineers from the control room. Novel remote support technology allows for remote access of EAM via online services. Remote access increases the flexibility of the electrophysiological lab, reduces travel time, and overcomes hospital access limitations especially during the COVID-19 pandemic. Here, we report on the feasibility and safety of EAM remote access for cardiac ablation procedures. Mapping and ablation were achieved by combining the EnsiteX™ EAM system and the integrated Ensite™ Connect Remote Support software, together with an integrated audiovisual solution system for remote support (Medinbox). Communication between the operator and the remote support was achieved using an incorporated internet-based common communication platform (Zoom™), headphones, and high-resolution cameras. We investigated 50 remote access–assisted consecutive electrophysiological procedures from September 2022 to February 2023 (remote group). The data were compared with matched patients (n = 50) with onsite support from the control room (control group). The median procedure time was 100 min (76, 120; remote) vs. 86 min (60, 110; control), P = 0.090. The procedural success (both groups 100%, P = 0.999) and complication rate (remote: 2%, control: 0%, P = 0.553) were comparable between the groups. Travel burden could be reduced by 11 280 km. Remote access for EAM was feasible and safe in this single-centre study. Procedural data were comparable to procedures with onsite support. In the future, this new solution might have a great impact on facilitating electrophysiological procedures.Keywords
Funding Information
- von Abbott Medical
This publication has 15 references indexed in Scilit:
- Pulsed Field Ablation-Based Pulmonary Vein Isolation Using a Simplified Single-Access Single-Catheter Approach ― The Fast and Furious PFA Study ―Circulation Journal, 2023
- High-Power Short-Duration Lesion Index-Guided Posterior Wall Isolation beyond Pulmonary Vein Isolation for Persistent Atrial FibrillationJournal of Clinical Medicine, 2023
- Very high-power short-duration ablation for pulmonary vein isolation utilizing a very-close protocol—the FAST AND FURIOUS PVI studyEP Europace, 2022
- Characterization of high-density mapping in catheter ablation for persistent atrial fibrillation: results from the Advisor™ HD Grid Mapping Catheter Observational studyJournal of Interventional Cardiac Electrophysiology, 2022
- Single very high-power short-duration application for successful ablation of frequent premature ventricular contractionsEP Europace, 2021
- Remote operation for non-fluoroscopic navigation of complex tachycardiasJournal of Interventional Cardiac Electrophysiology, 2020
- Guidance for Cardiac Electrophysiology During the COVID-19 Pandemic from the Heart Rhythm Society COVID-19 Task Force; Electrophysiology Section of the American College of Cardiology; and the Electrocardiography and Arrhythmias Committee of the Council on Clinical Cardiology, American Heart AssociationCirculation, 2020
- Safety and outcome of very high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillationEP Europace, 2019
- High‐power short‐duration versus standard radiofrequency ablation: Insights on lesion metricsJournal of Cardiovascular Electrophysiology, 2018
- Positionspapier der Deutschen Gesellschaft für Kardiologie zur KardioanalgosedierungDer Kardiologe, 2017