An In Vivo Model of Femtosecond Laser Intrastromal Refractive Surgery
Authors:
- Kimberly G YenKYKimberly G Yen
- Samir SayeghSSSamir Sayegh
- Frieder LoeselFLFrieder Loesel
- Christine EckhoffCEChristine Eckhoff
- Christopher HorvathCHChristopher Horvath
- Mali MeunierMMMali Meunier
- Tibor JuhaszTJTibor Juhasz
- Ron M KurtzRKRon M Kurtz
- 1 November 1999
- journal article
- research article
- Published by SLACK, Inc. in Ophthalmic Surgery, Lasers and Imaging Retina
- Vol. 30 (9) , 742-749
Abstract
* BACKGROUND AND OBJECTIVE: To develop an animal model for evaluation of femtosecond laser intrastromal refractive surgery. * METHODS: Intrastromal photodisruption was performed in New Zealand Albino rabbits using a femtosecond laser system. This surgical pattern consisted of a 100 µm-tick pyramid of laser pulses starting 180 µm below the corneal surface. Animals underwent serial slit lamp examinations and corneal thickness measurements at 1,3,7,14, and 28 days, then monthly up to 1 year. * RESULTS: Approximately 70 µm of central corneal thinning were seen at 1 week, remaining stable up to 7 months. * CONCLUSIONS: Intrastromal photodisruption with femtosecond lasers produced consistent changes in corneal thickness without loss of corneal transparency. These changes were more stable than those produced with excimer laser procedures in a similar animal model. [Ophthalmic Surg Lasers 1999;30:742-749.]Keywords
This publication has 17 references indexed in Scilit:
- Posterior corneal surface topographic changes after laser in situ keratomileusis are related to residual corneal bed thickness11The authors have no propriety interests in any materials or methods described in this article.Ophthalmology, 1999
- Laser in situ keratomileusis versus photorefractive keratectomy: an update on indications and safetyOphthalmology, 1998
- Factors determining the refractive effects of intrastromal photorefractive keratectomy with the picosecond laserJournal of Cataract & Refractive Surgery, 1997
- Time-resolved observations of shock waves and cavitation bubbles generated by femtosecond laser pulses in corneal tissue and waterLasers in Surgery and Medicine, 1996
- Myopic Intrastromal Photorefractive Keratectomy With the Neodymium-Yttrium Lithium Fluoride Picosecond Laser in the Cat CorneaArchives of Ophthalmology (1950), 1995
- Corneal Ablations Produced by the Neodymium Doped Yttrium-Lithium-Fluoride Picosecond LaserCornea, 1994
- Analysis of repeated categorical data using generalized estimating equationsStatistics in Medicine, 1994
- Corneal Ablation by Nanosecond, Picosecond, and Femtosecond Lasers at 532 and 625 nmArchives of Ophthalmology (1950), 1989
- Picosecond optical breakdown: Tissue effects and reduction of collateral damageLasers in Surgery and Medicine, 1989
- The mechanical properties of the rabbit and human corneaJournal of Biomechanics, 1986