Does Abutment Collar Length Affect Abutment Screw Loosening After Cyclic Loading?
- 1 July 2015
- journal article
- research article
- Published by American Academy of Implant Dentistry in Journal of Oral Implantology
- Vol. 41 (S1) , 346-351
Abstract
A significant vertical space that is corrected with vertical ridge augmentation may necessitate selection of longer abutments, which would lead to an increased vertical cantilever. This study investigated the influence of different abutment collar heights on single-unit dental implant screw-loosening after cyclic loading. Fifteen implant-abutment assemblies each consisted of an internal hexagonal implant were randomly assigned to 3 groups: Group1, consisting of 5 abutments with 1.5 mm gingival height (GH); Group2, 5 abutments with 3.5 mm GH; and Group3, 5 abutments with 5.5 mm GH. Each specimen was mounted in transparent auto-polymerizing acrylic resin block, and the abutment screw was tightened to 35 Ncm with an electric torque wrench. After 5 minutes, initial torque loss (ITL) was recorded for all specimens. Metal crowns were fabricated with 45° occlusal surface and were placed on the abutments. A cyclic load of 75 N and frequency of 1 Hz were applied perpendicular to the long axis of each specimen. After 500 000 cycles, secondary torque loss (STL) was recorded. One-way ANOVA analysis was used to evaluate the effects of abutment collar height before and after cyclic loading. One-way ANOVA showed that ITL among the groups was not significantly different (P = .52), while STL was significantly different among the groups (P = .008). Post-hoc Tukey HSD tests showed that STL values were significantly different between the abutments with 1.5 mm GH (Group1) and with 5.5 mm GH (Group3) (P = .007). A paired comparison t-test showed that cyclic loading significantly influenced the STL in comparison with the ITL in each group. Within the limitations of this study, it can be concluded that increase in height of the abutment collar could adversely affect the torque loss of the abutment screw.Keywords
This publication has 33 references indexed in Scilit:
- Effect of repeated screw joint closing and opening cycles on implant prosthetic screw reverse torque and implant and screw thread morphologyThe Journal of Prosthetic Dentistry, 2011
- Osseointegrated Implant Fracture: Causes and TreatmentJournal of Oral Implantology, 2011
- Effect of unilateral misfit on preload of retention screws of implant-supported prostheses submitted to mechanical cyclingJournal of Prosthodontic Research, 2011
- Prospective clinical evaluation of 1920 Morse taper connection implants: results after 4 years of functional loadingClinical Oral Implants Research, 2009
- Preload and torque removal evaluation of three different abutment screws for single standing implant restorationsJournal of Applied Oral Science, 2008
- Peri-Implant Bone Level Around Implants With Platform-Switched Abutments: Preliminary Data From a Prospective StudyJournal of Oral and Maxillofacial Surgery, 2007
- Biomechanical analysis on platform switching: is there any biomechanical rationale?Clinical Oral Implants Research, 2007
- Effect of Casting Procedures on Screw Loosening in UCLA‐Type AbutmentsJournal of Prosthodontics, 2006
- Limits of human bite strengthThe Journal of Prosthetic Dentistry, 1986
- A 15-year study of osseointegrated implants in the treatment of the edentulous jawInternational Journal of Oral Surgery, 1981