Electrochemical Kinetic Characterization of Redox Mediated Glucose Oxidase Reactions: A Simplified Approach
- 15 January 2008
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 20 (2) , 163-169
Abstract
One of the main drawbacks affecting first‐generation electrochemical biosensors in the analysis of real matrices is the interference of electroactive species present in the sample under investigation. Several approaches have been attempted to overcome this problem in the past ten years but the best results were achieved by using mediated based electrochemical biosensors. Despite this, the kinetic of the redox mediators‐enzymatic proteins interaction has not been studied deeply enough. In this work we have developed a theoretical‐methodological approach for the characterization of the kinetic of interaction between redox enzymes and substrates and/or redox mediators. Particularly, the interaction of glucose oxidase (GOx) with several commercially available redox mediators has been studied by means of amperometry and cyclic voltammetry. The main kinetic parameters for different mediators were exploited and discussed with the aim of finding the best mediator for a glucose biosensor to be used on real samples.Keywords
This publication has 26 references indexed in Scilit:
- Electroactive Nanostructured Membranes (ENM): Synthesis and Electrochemical Properties of Redox Mediator‐Modified Gold Nanoparticles Using a Dendrimer Layer‐by‐Layer ApproachElectroanalysis, 2007
- Preserved enzymatic activity of glucose oxidase immobilized on an unmodified electrodeElectrochemistry Communications, 2006
- Nitric Oxide Biosensors Based on the Immobilization of Hemoglobin on Mesoporous Titania ElectrodesElectroanalysis, 2006
- A glucose biosensor using methyl viologen redox mediator on carbon film electrodesAnalytica Chimica Acta, 2005
- Evaluation of osmium(II) complexes as mediators accessible for biosensorsSensors and Actuators B: Chemical, 2000
- Competitive enzyme immunosensor developed on a renewable carbon paste electrode supportAnalytica Chimica Acta, 1999
- Electrochemical Evaluation of Redox Enzyme Reaction Kinetics Based on Mediated Bioelectrocatalysis in SolutionChemistry Letters, 1996
- Polyferrocenes as mediators in amperometric biosensors for glucoseAnalytica Chimica Acta, 1993
- Mediated electron transfer from glucose oxidase at a ferrocene‐modified graphite electrodeElectroanalysis, 1989
- Amperometric sensor for pyruvate with immobilized pyruvate oxidaseAnalytica Chimica Acta, 1987