Association between routine and standardized blood pressure measurements and left ventricular hypertrophy among patients on hemodialysis
Authors:
- Jaspreet KhanguraJKJaspreet Khangura
- Bruce F CulletonBCBruce F Culleton
- Braden J MannsBMBraden J Manns
- Jianguo ZhangJZJianguo Zhang
- Lianne BarniehLBLianne Barnieh
- Michael WalshMWMichael Walsh
- Scott W KlarenbachSKScott W Klarenbach
- Marcello TonelliMTMarcello Tonelli
- Magdalena SarnaMSMagdalena Sarna
- Brenda R HemmelgarnBHBrenda R Hemmelgarn
- The Alberta Kidney Disease NetworkTNThe Alberta Kidney Disease Network
Open Access
- 24 June 2010
- journal article
- research article
- Published by Springer Nature in BMC Nephrology
- Vol. 11 (1) , 1-8
Abstract
Background: Left ventricular (LV) hypertrophy is common among patients on hemodialysis. While a relationship between blood pressure (BP) and LV hypertrophy has been established, it is unclear which BP measurement method is the strongest correlate of LV hypertrophy. We sought to determine agreement between various blood pressure measurement methods, as well as identify which method was the strongest correlate of LV hypertrophy among patients on hemodialysis. Methods: This was a post-hoc analysis of data from a randomized controlled trial. We evaluated the agreement between seven BP measurement methods: standardized measurement at baseline; single pre- and post-dialysis, as well as mean intra-dialytic measurement at baseline; and cumulative pre-, intra- and post-dialysis readings (an average of 12 monthly readings based on a single day per month). Agreement was assessed using Lin's concordance correlation coefficient (CCC) and the Bland Altman method. Association between BP measurement method and LV hypertrophy on baseline cardiac MRI was determined using receiver operating characteristic curves and area under the curve (AUC). Results: Agreement between BP measurement methods in the 39 patients on hemodialysis varied considerably, from a CCC of 0.35 to 0.94, with overlapping 95% confidence intervals. Pre-dialysis measurements were the weakest predictors of LV hypertrophy while standardized, post- and inter-dialytic measurements had similar and strong (AUC 0.79 to 0.80) predictive power for LV hypertrophy. Conclusions: A single standardized BP has strong predictive power for LV hypertrophy and performs just as well as more resource intensive cumulative measurements, whereas pre-dialysis blood pressure measurements have the weakest predictive power for LV hypertrophy. Current guidelines, which recommend using pre-dialysis measurements, should be revisited to confirm these results.Keywords
This publication has 31 references indexed in Scilit:
- Effect of Frequent Nocturnal Hemodialysis vs Conventional Hemodialysis on Left Ventricular Mass and Quality of LifeJAMA, 2007
- IntroductionJournal of the American Society of Nephrology, 2006
- Home blood pressure monitoring improves the diagnosis of hypertension in hemodialysis patientsKidney International, 2006
- Out-of-Hemodialysis-Unit Blood Pressure Is a Superior Determinant of Left Ventricular HypertrophyHypertension, 2006
- Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady‐state free precession imaging sequencesJournal of Magnetic Resonance Imaging, 2003
- Editorials: Assessment of Blood Pressure in Hemodialysis PatientsSeminars in Dialysis, 2002
- Prediction of hypertension in chronic hemodialysis patientsKidney International, 2001
- Outcome and risk factors for left ventricular disorders in chronic uraemiaNephrology Dialysis Transplantation, 1996
- Impact of left ventricular hypertrophy on survival in end-stage renal diseaseKidney International, 1989
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986