Atrial Fibrillation Detection Using an Improved Multi-Scale Decomposition Enhanced Residual Convolutional Neural Network
Open Access
- 4 July 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 89152-89161
Abstract
Atrial fibrillation, the most common sustained arrhythmia, is still a big challenge for researchers in the medical field. Many studies attempt to realize intelligent classification of AF based on deep learning methods. However, many of the studies focused on investigations of relatively simple datasets collected from a relatively small number of subjects. On the other hand, sophisticated preprocessing is usually adopted to analysis the ECG signals. These two factors significantly affect the generalization ability of the trained models for complicated date sets collected from a large number of subjects. In order to address this problem, an improved multi-scale decomposition enhanced residual convolutional neural network is proposed. The proposed method is applied to the large single-lead ECG dataset provided by the PhysioNet/CinC Challenge 2017, and good classification accuracy is suggested by the testing results. In the proposed method, the original ECG record with a large difference in length is resegmented into short samples of 9 seconds. Then, using the derived wavelet frame decomposition, the segmented short samples are decomposed and reconstituted into sub-signal samples of different scales. We trained the fast down-sampling residual convolutional neural networks (FDResNets) with the original short-signal dataset and the reconstructed dataset of each scale. The transfer learning technique is then applied to couple the three FDResNets with good performance into a multi-scale decomposition enhanced residual convolutional neural network (MSResNet). The FDResNet trained by the 0, 9.375 Hz reconstruction dataset achieved the best performance. After six-fold cross-validation, the average test accuracy reached 87.12%, and the average comprehensive F1 score reached 85.29%. The average test accuracy of the multi-scale residual neural network reached 92.1%, and the average overall F1 score reached 89.9%.Keywords
Funding Information
- National Natural Science Foundation of China (51605403)
- Natural Science Foundation of Guangdong Province (2015A030310010)
- Fundamental Research Funds for the Central Universities (20720190009)
This publication has 36 references indexed in Scilit:
- Image-Based Quantitative Analysis of Gold Immunochromatographic Strip via Cellular Neural Network ApproachIEEE Transactions on Medical Imaging, 2014
- Convolutional Neural Networks for Sentence Classification2014
- Complex Fractionated Atrial ElectrogramsCirculation: Arrhythmia and Electrophysiology, 2011
- A novel feature selection approach for biomedical data classificationJournal of Biomedical Informatics, 2010
- Enhancement of signal denoising and multiple fault signatures detecting in rotating machinery using dual-tree complex wavelet transformMechanical Systems and Signal Processing, 2010
- Integrative data mining in systems biology: from text to network miningArtificial Intelligence in Medicine, 2007
- Management of atrial fibrillationThe Lancet, 2007
- Characterising the discrete wavelet transform of an ECG signal with simple parameters for use in automated diagnosis2002
- Filter bank-based processing of the stress ECG2002
- PhysioBank, PhysioToolkit, and PhysioNetCirculation, 2000