Biomechanical Comparison of Arthroscopically Performable Techniques for Suprapectoral Biceps Tenodesis
- 27 June 2011
- journal article
- research article
- Published by Wiley in Arthroscopy
- Vol. 27 (8) , 1036-1047
Abstract
Purpose: The aim of this study was to biomechanically compare the cyclic and ultimate failure load (UFL) of 4 widely used techniques for arthroscopically performable suprapectoral tenodesis of the long head of the biceps tendon (LHB). Methods: We used 28 fresh‐frozen human cadaveric specimens (mean age, 65 years [range, 43 to 78 years; SD, 6.7 years]; 43% male specimens) to investigate 4 different techniques for LHB tenodesis. All techniques were performed in an open manner, with localization at the entrance of the bicipital groove. Two suture anchor techniques (Healix [DePuy Mitek, Raynham, MA], 5.5 mm, with modified lasso‐loop stitch; BioSwiveLock [Arthrex, Naples, FL], 5.5 mm, with interlocking Krackow stitch) and two techniques using tenodesis screws (Bio‐Tenodesis screw [Arthrex], 8 × 23 mm; Biceptor [Smith & Nephew, Andover, MA], 8 × 25 mm) were investigated. Under a 10‐N preload, an axial cyclic load with 100 cycles, 1‐Hz frequency, and 50‐N maximum load was applied. UFL was evaluated with an axial traction of 0.2 mm/s. LHB displacement during testing was measured by 3‐dimensional photogrammetry. Results: All techniques had a mean displacement of less than 3 mm after cyclic loading. The highest UFL was measured with the Bio‐Tenodesis screw (mean, 218.3 N; range, 134.0 to 313.0 N; SD, 59.7 N) and the lowest with the BioSwiveLock (mean, 111.2 N; range, 60.0 to 156.8 N; SD, 32.3 N). The Healix had the second highest UFL (mean, 187.1 N; range, 144.7 to 245.0 N; SD, 35.5 N), followed by the Biceptor (mean, 173.9 N; range, 147.0 to 209.3 N; SD, 27.2 N). There was no significant difference between the Healix, Bio‐Tenodesis screw, and Biceptor ( P > .05), but the Healix and Bio‐Tenodesis screw had a significantly higher UFL than the BioSwiveLock ( P < .01). The failure mode was either suture cutout or failure at the anchor‐suture‐bone interface or of the tendon itself and was generally dependent on technique. Conclusions: All techniques resisted cyclic testing without a higher grade of displacement, and all devices except the BioSwiveLock had a satisfactory UFL whereas different failure mechanisms were present. The modified lasso‐loop stitch provides sufficient tendon fixation and is equivalent to interference screws. Clinical Relevance: The lasso‐loop suture anchor technique is an appropriate alternative for suprapectoral LHB tenodesis compared with tenodesis screw techniques.Keywords
Funding Information
- Arthrex
- Smith and Nephew
- DePuy Mitek
This publication has 26 references indexed in Scilit:
- Biomechanical Evaluation of 2 Arthroscopic Biceps TenodesesThe American Journal of Sports Medicine, 2009
- Arthroscopic Treatment of Isolated Type II SLAP LesionsThe American Journal of Sports Medicine, 2009
- Tenotomy versus Tenodesis in the Management of Pathologic Lesions of the Tendon of the Long Head of the Biceps BrachiiThe American Journal of Sports Medicine, 2008
- The Proximal Biceps as a Pain Generator and Results of TenotomySports Medicine and Arthroscopy Review, 2008
- The long head of biceps and associated tendinopathyThe Journal of Bone and Joint Surgery. British volume, 2007
- A New Technique to Improve Tissue Grip: “The Lasso‐Loop Stitch”Arthroscopy, 2006
- The Biomechanical Evaluation of Four Fixation Techniques for Proximal Biceps TenodesisArthroscopy, 2005
- Long head biceps tenotomy versus tenodesis: A cadaveric biomechanical analysisArthroscopy, 2005
- Arthroscopic biceps tenodesisArthroscopy, 2004
- DISLOCATION AND ELONGATION OF THE LONG HEAD OF THE BICEPS BRACHIIAnnals of Surgery, 1936