Human Biodistribution and Radiation Dosimetry of 82Rb
Authors:
Open Access
- 16 September 2010
- journal article
- research article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 51 (10) , 1592-1599
Abstract
Prior estimates of radiation-absorbed doses from 82Rb, a frequently used PET perfusion tracer, yielded discrepant results. We reevaluated 82Rb dosimetry using human in vivo biokinetic measurements. Methods: Ten healthy volunteers underwent dynamic PET/CT (6 contiguous table positions, each with separate 82Rb infusion). Source organ volumes of interest were delineated on the CT images and transferred to the PET images to obtain time-integrated activity coefficients. Radiation doses were estimated using OLINDA/EXM 1.0. Results: The highest mean absorbed organ doses (μGy/MBq) were observed for the kidneys (5.81), heart wall (3.86), and lungs (2.96). Mean effective doses were 1.11 ± 0.22 and 1.26 ± 0.20 μSv/MBq using the tissue-weighting factors of the International Commission on Radiological Protection (ICRP), publications 60 and 103, respectively. Conclusion: Our current 82Rb dosimetry suggests reasonably low radiation exposure. On the basis of this study, a clinical 82Rb injection of 2 × 1,480 MBq (80 mCi) would result in a mean effective dose of 3.7 mSv using the weighting factors of the ICRP 103—only slightly above the average annual natural background exposure in the United States (3.1 mSv).Keywords
This publication has 13 references indexed in Scilit:
- Recent advances in cardiac PET and PET/CT myocardial perfusion imagingJournal of Nuclear Cardiology, 2009
- Cardiac Positron Emission TomographyJACC, 2009
- MIRD Pamphlet No. 21: A Generalized Schema for Radiopharmaceutical Dosimetry—Standardization of NomenclatureJournal of Nuclear Medicine, 2009
- Radiopharmaceuticals for Nuclear Cardiology: Radiation Dosimetry, Uncertainties, and RiskJournal of Nuclear Medicine, 2008
- Radiation Dose to Patients From Cardiac Diagnostic ImagingCirculation, 2007
- New Technology for Noninvasive Evaluation of Coronary Artery DiseaseCirculation, 2007
- Issues regarding radiation dosage of cardiac nuclear and radiography proceduresJournal of Nuclear Cardiology, 2006
- OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine.2005
- SAAM II: Simulation, analysis, and modeling software for tracer and pharmacokinetic studiesMetabolism, 1998