Real-Time Markerless Tooth Detection Towards Dynamic Robot-Assisted Dental Implant Navigation
Authors:
- Vasile BulbucanVBVasile Bulbucan
- Daria PislaDPDaria Pisla
- Paul TucanPTPaul Tucan
- Cristian DinuCDCristian Dinu
- Calin VaidaCalin Vaida
- Rares MocanRMRares Mocan
- Mihaela BaciutMBMihaela Baciut
- Sebastian StoiaSSSebastian Stoia
- Mihaela HedesiuMHMihaela Hedesiu
- Ionut ZimaIZIonut Zima
- Doina PislaDoina Pisla
- TEAM Project GroupTGTEAM Project Group
Open Access
- 5 June 2026
- journal article
- research article
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (6) , 345
Abstract
Background/Objectives: Dynamic navigation and robot-assisted implant workflows depend on robust intraoral perception. Marker-based tracking introduces workflow complexity and is sensitive to occlusions, motivating markerless alternatives. This study evaluates whether a single-stage YOLO instance segmentation model (YOLO-seg) can provide a practical markerless perception layer for dental navigation, combining accurate per-tooth delineation with low, predictable inference latency. Methods: YOLO-seg was trained end to end on an intraoral RGB corpus of 400 training, 20 validation, and 100 testing images, combining a public source and a partner-hospital in-house set. A two-stage YOLO + SAM baseline was implemented for comparison. Segmentation quality was evaluated on a 50-image held-out clinical test set at three complementary levels (per-instance matching, per-class union, and global union), with paired Wilcoxon signed-rank tests, Cliff’s delta effect sizes, and 95% bootstrap confidence intervals. Runtime was assessed under matched inference-only and end-to-end conditions on N = 100 frames at a 640 × 640 resolution on an NVIDIA RTX A2000 GPU. Results: YOLO-seg significantly outperformed YOLO + SAM across all primary metrics, with very large effect sizes (Cliff’s delta: 0.76–0.94; Wilcoxon p < 10−8 on every metric except precision at IoU ≥ 0.5). YOLO-seg reached AP50 = 0.716 and recall = 0.973 versus 0.383 and 0.398 for YOLO + SAM. Under matched inference-only timing, YOLO-seg ran at 27.08 ms per frame (36.9 FPS) versus 1302.78 ms (0.77 FPS), an approximately 48-fold latency gap intrinsic to the two-stage forward pass. Conclusions: YOLO-seg shows strong potential as a 2D perception module for dental navigation, balancing per-instance segmentation fidelity with real-time feasibility under the tested conditions. These results support its use as a 2D perception front-end for future integration with stereo-based 3D reconstruction and robot-assisted navigation; 3D registration accuracy, implant-placement error, and robotic execution remain outside the scope of the present study.Keywords
Funding Information
- Romanian Hub for Artificial Intelligence-HRIA (351416, PNRR-III-C9-2023-I8)
- Technologically Enabled Advancements in Dental Medicine (100418/29.08.2025)
This publication has 24 references indexed in Scilit:
- Exploring YOLO applications in dentistry through a systematic review of detection and segmentation modelsDiscover Artificial Intelligence, 2026
- Towards a zero-shot low-latency navigation for open surgery augmented reality applicationsInternational Journal of Computer Assisted Radiology and Surgery, 2025
- Accuracy in dental implant placement: A systematic review and meta-analysis comparing computer-assisted (static, dynamic, robotics) and noncomputer-assisted (freehand, conventional guide) approachesThe Journal of Prosthetic Dentistry, 2025
- SegmentAnyTooth: An open-source deep learning framework for tooth enumeration and segmentation in intraoral photosJournal of Dental Sciences, 2025
- Tackling the small data problem in medical image classification with artificial intelligence: a systematic reviewProgress in Biomedical Engineering, 2024
- Segment anything in medical imagesNature Communications, 2024
- An intelligent tracking system for surgical instruments in complex surgical environmentExpert Systems with Applications, 2023
- Accuracy assessment of dynamic navigation during implant placement: A systematic review and meta-analysis of clinical studies in the last 10 yearsJournal of Dentistry, 2023
- Optical and Electromagnetic Tracking Systems for Biomedical Applications: A Critical Review on Potentialities and LimitationsIEEE Reviews in Biomedical Engineering, 2019
- Dominance statistics: Ordinal analyses to answer ordinal questions.Psychological Bulletin, 1993