Abstract
We describe a new method to accomplish multiplexed, absolute protein quantification in a targeted fashion. The approach draws upon the recently developed neutron encoding (NeuCode) metabolic labeling strategy and parallel reaction monitoring (PRM). Since PRM scanning relies upon high-resolution tandem mass spectra for targeted protein quantification, incorporation of multiple NeuCode labeled peptides permits high levels of multiplexing that can be accessed from high-resolution tandem mass spectra. Here we demonstrate this approach in cultured cells by monitoring a viral infection and the corresponding viral protein production over many infection time points in a single experiment. In this context the NeuCode PRM combination affords up to 30 channels of quantitative information in a single MS experiment.Keywords
Funding Information
- National Institute of Allergy and Infectious Diseases (AI091646, AI104317)
- Division of Graduate Education (DGE-1256259)
- U.S. Department of War
- National Institute of General Medical Sciences (GM080148, T32GM008505)
This publication has 53 references indexed in Scilit:
- Applications of selected reaction monitoring (SRM)-mass spectrometry (MS) for quantitative measurement of signaling pathwaysMethods, 2013
- Statistical characterization of multiple-reaction monitoring mass spectrometry (MRM-MS) assays for quantitative proteomicsBMC Bioinformatics, 2012
- Protein Significance Analysis in Selected Reaction Monitoring (SRM) MeasurementsMolecular & Cellular Proteomics, 2012
- Mass Spectrometry-based Proteomics Using Q Exactive, a High-performance Benchtop Quadrupole Orbitrap Mass SpectrometerMolecular & Cellular Proteomics, 2011
- Sub-part-per-million Precursor and Product Mass Accuracy for High-throughput Proteomics on an Electron Transfer Dissociation-enabled Orbitrap Mass SpectrometerMolecular & Cellular Proteomics, 2010
- Automated Detection of Inaccurate and Imprecise Transitions in Peptide Quantification by Multiple Reaction Monitoring Mass SpectrometryClinical Chemistry, 2010
- Analysis of Tandem Mass Spectra by FTMS for Improved Large-Scale Proteomics with Superior Protein QuantificationAnalytical Chemistry, 2009
- Peptide Quantification Using 8-Plex Isobaric Tags and Electron Transfer Dissociation Tandem Mass SpectrometryAnalytical Chemistry, 2009
- Peptide and protein quantification using iTRAQ with electron transfer dissociationJournal of the American Society for Mass Spectrometry, 2008
- Multiple reaction monitoring for robust quantitative proteomic analysis of cellular signaling networksProceedings of the National Academy of Sciences, 2007