Abstract
In this paper, a soft upper-extremity passive robotic exosuit is presented. This exosuit intends to assist workers when they are carrying heavy loads. The feature of the proposed exosuit design is that it consists of a light plastic frame and a cable system mounted via joints on the frame. Polyethylene braid-style cables are used which have a high strength of extension up to 34kg and low deformability. Comparing to the rigid frame exoskeleton, the mass and the inertia of the cable are negligible. With the help of cable winding and locking mechanism, during the transporting phase of load carrying, the gravity of the load can be compensated by cables and redistributed on the shoulder and thigh. Hence the pressure of muscles on arm can be relieved. In order to have the optimal assistive effect, the positions of anchors and cable attachment points have been optimized. An experiment has been conducted with a preliminary prototype mounted on a mannequin test bench. Experiment result shows that with the help of this exosuit, the mannequin test bench can steadily hold its posture when a 10kg load is applied and meanwhile, its joint mobility is not affected when it is in the non-carrying-load mode.Keywords
This publication has 12 references indexed in Scilit:
- Design and embedded control of a soft elbow exosuit2018
- CRUX: A compliant robotic upper-extremity exosuit for lightweight, portable, multi-joint muscular augmentation2017
- Preliminary design and control of a soft exosuit for assisting elbow movements and hand grasping in activities of daily livingJournal of Rehabilitation and Assistive Technologies Engineering, 2017
- Soft exosuit for hip assistanceRobotics and Autonomous Systems, 2015
- Robotic Rehabilitation Devices of Human Extremities: Design Concepts and Functional Particularities2012
- Design of a Cable-Driven Arm Exoskeleton (CAREX) for Neural RehabilitationIEEE Transactions on Robotics, 2012
- Safety and tolerance of the ReWalk™exoskeleton suit for ambulation by people with complete spinal cord injury: A pilot studyThe Journal of Spinal Cord Medicine, 2012
- Muscle fatigue: what, why and how it influences muscle functionThe Journal of Physiology, 2008
- Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait RehabilitationIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2007