Alkylphosphocholines for intraocular lens coating
Authors:
- 1 March 2013
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 39 (3) , 438-445
Abstract
Purpose To assess the effect of alkylphosphocholine (APC)-coated intraocular lenses (IOLs) on human lens epithelial cell (LEC) proliferation in vitro and the corneal biocompatibility of APC in an organ culture model of human donor eyes. Setting Research Laboratory for Experimental Ophthalmology, Ludwig-Maximilians-University, Munich, Germany. Design Experimental study. Methods Six foldable IOLs differing in optic material were incubated with APC, washed in phosphate-buffered saline, and dried overnight. Intraocular lenses of the same lot served as uncoated controls. Each rehydrated IOL was placed in 1 well of a 24-well plate containing proliferating human LECs. Cell survival was tested by the tetrazolium-dye reduction assay 5 days later. Biocompatibility of the human corneal endothelium was assessed by a 24-hour incubation of human donor corneas with different concentrations of APC before the live/dead assay was performed. Results Human LEC proliferation was attenuated by APC-coated IOLs (P=.001). Coated hydrophilic acrylic IOLs were more effective inhibitors of human LEC proliferation than coated hydrophobic acrylic or silicone IOLs (P=.001). Alkylphosphocholines were well tolerated by the corneal endothelium in an organ culture model of human donor corneas up to a concentration of 1 mM (n = 12). Conclusions Results show that APCs are suitable agents for IOL coating without linker molecules. Coated IOLs can inhibit human LEC proliferation and were well tolerated by human donor corneas in organ culture. Financial Disclosure Dr. Eibl-Lindner holds the patent for “Intraocular lenses treated with alkylphosphocholines for pharmacological aftercataract prophylaxis,” international application no. PCT/EP2010/051490. No other author has a financial or proprietary interest in any material or method mentioned.Keywords
This publication has 21 references indexed in Scilit:
- Posterior capsule opacification and neodymium:YAG laser capsulotomy rates with a round-edged silicone and a sharp-edged hydrophobic acrylic intraocular lens 10 years after surgeryJournal of Cataract & Refractive Surgery, 2009
- Evaluating and defining the sharpness of intraocular lenses: Microedge structure of commercially available square-edged hydrophilic intraocular lensesJournal of Cataract & Refractive Surgery, 2009
- Randomized intraindividual comparison of posterior capsule opacification between a microincision intraocular lens and a conventional intraocular lensJournal of Cataract & Refractive Surgery, 2009
- Optic Edge Design as Long-term Factor for Posterior Capsular Opacification RatesOphthalmology, 2008
- Effect of square-edged intraocular lenses on neodymium:YAG laser capsulotomy rates in the United StatesJournal of Cataract & Refractive Surgery, 2007
- Effect of surface coating an acrylic intraocular lens with poly(2-methacryloyloxyethyl phosphorylcholine) polymer on lens epithelial cell line behaviorJournal of Cataract & Refractive Surgery, 2006
- Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edgesJournal of Cataract & Refractive Surgery, 2000
- Intraocular pressure change after neodymium:YAG capsulotomyJournal of Cataract & Refractive Surgery, 1997
- Neodymium:YAG laser damage on silicone intraocular lensesJournal of Cataract & Refractive Surgery, 1994
- Posterior capsule opacificationSurvey of Ophthalmology, 1992