A Fully Automated Visual Grading System for White Matter Hyperintensities of T2-Fluid Attenuated Inversion Recovery Magnetic Resonance Imaging
Authors:
Open Access
- 6 May 2023
- journal article
- research article
- Published by IMR Press in Journal of Integrative Neuroscience
- Vol. 22 (3) , 57
Abstract
Background: The Fazekas scale is one of the most commonly used visual grading systems for white matter hyperintensity (WMH) for brain disorders like dementia from T2-fluid attenuated inversion recovery magnetic resonance (MR) images (T2-FLAIRs). However, the visual grading of the Fazekas scale suffers from low-intra and inter-rater reliability and high labor-intensive work. Therefore, we developed a fully automated visual grading system using quantifiable measurements. Methods: Our approach involves four stages: (1) the deep learning-based segmentation of ventricles and WMH lesions, (2) the categorization into periventricular white matter hyperintensity (PWMH) and deep white matter hyperintensity (DWMH), (3) the WMH diameter measurement, and (4) automated scoring, following the quantifiable method modified for Fazekas grading. We compared the performances of our method and that of the modified Fazekas scale graded by three neuroradiologists for 404 subjects with T2-FLAIR utilized from a clinical site in Korea. Results: The Krippendorff’s alpha across our method and raters (A) versus those only between the radiologists (R) were comparable, showing substantial (0.694 vs. 0.732; 0.658 vs. 0.671) and moderate (0.579 vs. 0.586) level of agreements for the modified Fazekas, the DWMH, and the PWMH scales, respectively. Also, the average of areas under the receiver operating characteristic curve between the radiologists (0.80 ± 0.09) and the radiologists against our approach (0.80 ± 0.03) was comparable. Conclusions: Our fully automated visual grading system for WMH demonstrated comparable performance to the radiologists, which we believe has the potential to assist the radiologist in clinical findings with unbiased and consistent scoring.Keywords
Funding Information
- Korea Medical Device Development Fund (202015X34, KMDF-PR-20200901-0306)
This publication has 25 references indexed in Scilit:
- White matter hyperintensity and stroke lesion segmentation and differentiation using convolutional neural networksNeuroImage: Clinical, 2018
- Measuring inter-rater reliability for nominal data – which coefficients and confidence intervals are appropriate?BMC Medical Research Methodology, 2016
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Applied Logistic Regression2013
- Close Correlation between Quantitative and Qualitative Assessments of White Matter LesionsNeuroepidemiology, 2012
- FreeSurferNeuroImage, 2012
- Impact of White Matter Changes on Activities of Daily Living in Mild to Moderate DementiaEuropean Neurology, 2011
- Classification of White Matter Lesions on Magnetic Resonance Imaging in Elderly PersonsBiological Psychiatry, 2008
- White matter hyperintensities are significantly associated with cortical atrophy in Alzheimer's diseaseJournal of Neurology, Neurosurgery & Psychiatry, 2004
- Euclidean Distance as a Similarity Metric for Principal Component AnalysisMonthly Weather Review, 2001