A parametric study of the factors affecting the fatigue strength of porous coated Ti‐6A1‐4V implant alloy
Authors:
- 1 November 1990
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 24 (11) , 1483-1501
Abstract
The high cycle fatigue strength of porous coated Ti‐6Al‐4V is approximately 75% less than the fatigue strength of uncoated Ti‐6Al‐4V. This study separates the effects of three parameters thought to be responsible for this reduction: interfacial geometry, microstructure, and surface alternations brought about by sintering. To achieve the goal of one parameter variations, hydrogen‐alloying treatments, which refined the lamellar microstructure of β‐annealed and porous coated Ti‐6Al‐4V, were formulated. The fatigue strength of smooth‐surfaced Ti‐6Al‐4V subjected to hydrogen‐alloying treatments is 643–669 MPa, significantly greater than the fatigue strength of β‐annealed Ti‐6Al‐4V (497 MPa) and also greater than the fatigue strength of preannealed, equiaxed Ti‐6Al‐4V (590 MPa). The fatigue strength of porous coated Ti‐6Al‐4V, however, is independent of microstructure. This leads to the conclusion that the notch effect of the surface porosity does not allow the material to take advantage of the superior fatigue crack initation resistance of a refined α‐grain size. Thus, sinternecks act as initiated microcracks and fatigue of porous coated Ti‐6Al‐4V is propagation controlled.Keywords
This publication has 26 references indexed in Scilit:
- Parametric analysis of interfacial stress concentrations in porous coated implantsJournal of Applied Biomaterials, 1990
- Loosening of Cobalt Chrome Beads from a Porous-Coated Acetabular ComponentClinical Orthopaedics and Related Research, 1988
- Fracture of the Porous-Coated Metal Tray of a Biologically Fixed Knee ProsthesisClinical Orthopaedics and Related Research, 1988
- Bead loosening in porous metal coated orthopaedi implants: a case studyClinical Materials, 1987
- Fatigue properties of cast and heat treated Ti6Al4V alloy for anatomic hip prosthesesBiomaterials, 1987
- Morphological Characterization of Porous Coatings1987
- Fatigue properties of carbon‐ and porous‐coated Ti-6Al-4V alloyJournal of Biomedical Materials Research, 1984
- Titanium Implants with Porous Structures for Bone Ingrowth: A General Approach1983
- Fatigue fractures of the femoral component of Charnley and Charnley‐Müller type total hip prosthesesJournal of Biomedical Materials Research, 1975
- Crack Growth Under Cyclic CompressionJournal of Basic Engineering, 1969