Low-dose cone-beam CT (LD-CBCT) reconstruction for image-guided radiation therapy (IGRT) by three-dimensional dual-dictionary learning
Open Access
- 12 August 2020
- journal article
- research article
- Published by Springer Nature in Radiation Oncology
- Vol. 15 (1) , 1-9
Abstract
Background: To develop a low-dose cone beam CT (LD-CBCT) reconstruction method named simultaneous algebraic reconstruction technique and dual-dictionary learning (SART-DDL) joint algorithm for image guided radiation therapy (IGRT) and evaluate its imaging quality and clinical application ability.Methods: In this retrospective study, 62 CBCT image sets from February 2018 to July 2018 at west china hospital were randomly collected from 42 head and neck patients (mean [standard deviation] age, 49.7 [11.4] years, 12 females and 30 males). All image sets were retrospectively reconstructed by SART-DDL (resultant D-CBCT image sets) with 18% less clinical raw projections. Reconstruction quality was evaluated by quantitative parameters compared with SART and Total Variation minimization (SART-TV) joint reconstruction algorithm with pairedttest. Five-grade subjective grading evaluations were done by two oncologists in a blind manner compared with clinically used Feldkamp-Davis-Kress algorithm CBCT images (resultant F-CBCT image sets) and the grading results were compared by paired Wilcoxon rank test. Registration results between D-CBCT and F-CBCT were compared. D-CBCT image geometry fidelity was tested.Results: The mean peak signal to noise ratio of D-CBCT was 1.7 dB higher than SART-TV reconstructions (P < .001, SART-DDL vs SART-TV, 36.36 ± 0.55 dB vs 34.68 ± 0.28 dB). All D-CBCT images were recognized as clinically acceptable without significant difference with F-CBCT in subjective grading (P > .05). In clinical registration, the maximum translational and rotational difference was 1.8 mm and 1.7 degree respectively. The horizontal, vertical and sagittal geometry fidelity of D-CBCT were acceptable.Conclusions: The image quality, geometry fidelity and clinical application ability of D-CBCT are comparable to that of the F-CBCT for head-and-neck patients with 18% less projections by SART-DDL.Keywords
Funding Information
- National Natural Science Foundation of China (81803056)
This publication has 22 references indexed in Scilit:
- Noise correlation in CBCT projection data and its application for noise reduction in low‐dose CBCTMedical Physics, 2014
- MR-guidance – a clinical study to evaluate a shuttle- based MR-linac connection to provide MR-guided radiotherapyRadiation Oncology, 2014
- Reconstruction of magnetic resonance imaging by three‐dimensional dual‐dictionary learningMagnetic Resonance in Medicine, 2013
- Improved Clinical Outcomes With High-Dose Image Guided Radiotherapy Compared With Non-IGRT for the Treatment of Clinically Localized Prostate CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Effects of the penalty on the penalized weighted least-squares image reconstruction for low-dose CBCTPhysics in Medicine & Biology, 2011
- GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variationMedical Physics, 2010
- Iterative image reconstruction for CBCT using edge‐preserving priorMedical Physics, 2008
- Low-dose CBCT Imaging for External Beam RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Radiation Dose From Cone Beam Computed Tomography for Image-Guided Radiation TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- $rm K$-SVD: An Algorithm for Designing Overcomplete Dictionaries for Sparse RepresentationIEEE Transactions on Signal Processing, 2006