Cortical bone perfusion in plated fracutured sheep tibiae
- 1 September 1995
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 13 (5) , 715-724
Abstract
The limited contact dynamic compression plate and partial contact plate were designed to decrease contact with cortical bone in an attempt to decrease cortical ischemia, remodeling, and eventual porosis under the plate after use of standard dynamic compression plates. This study quantified cortical bone blood flow beneath the plate with these three different designs in a sheep tibia fracture model. In 18 skeletally immature sheep, the right tibia was fractured and then was internally fixed with an interfragmentary screw and a dynamic compression plate, limited contact dynamic compression plate, or partial contact plate. At 12 weeks, cortical bone perfusion was assessed with laser Doppler flowmetry in nine areas beneath the plate. The baseline (before fracture) cortical bone cell flux averaged 100 ± 60 mV. After fracture, this decreased to 60 ± 48 mV (p < 0.0003); immediately after plating, the perfusion averaged 29 ± 25 mV (p < 0.01). Cortical bone perfusion then increased to 106 ± 52, 165 ± 71, and 163 ± 71 mV at 2, 6, and 12 weeks after fracture (p < 0.001 for all when compared with values after plating). No significant differences in cortical perfusion were seen between the types of plate. Cortical porosity under the plate was assessed with digital density analysis of microradiographs of this region. No significant difference was seen between the types of plate in this analysis or in biomechanical and disulphine blue perfusion analysis. Thus, no significant advantage was seen for the new plate designs used in this model. This lack of advantage may be a result of the immature animals used in the study, the protocol for blood flow measurement, the invasive periosteal stripping employed to create the fracture, or all three. However, as advantages with the new plate designs have been seen in other studies, this area warrants further investigation.Keywords
This publication has 19 references indexed in Scilit:
- Cortical bone microperfusion: Response to ischemia and changes in major arterial blood flowJournal of Orthopaedic Research, 1992
- The concept of biological plating using the limited contact — dynamic compression plate (LC-DCP)Injury, 1991
- Effect of fracture fixation on cortical bone blood flowJournal of Orthopaedic Research, 1990
- Radiographic videodensitometry for quantitative monitoring of experimental bone healingBritish Journal of Radiology, 1989
- Laser doppler flowmetry for bone blood flow measurements: Helium–neon laser light attenuation and depth of perfusion assessmentJournal of Orthopaedic Research, 1989
- Compression-plate fixation of acute fractures of the diaphyses of the radius and ulna.Journal of Bone and Joint Surgery, 1989
- A Method for the Geometric and Densitometric Standardization of Intraoral RadiographsJournal of Periodontology, 1983
- Effect of Plates on Cortical Bone Perfusion1981
- Experience with the dynamic compression plate (DCP) in 418 recent fractures of the tibial shaftInjury, 1975
- Bone Structure Changes in the Dog Under Rigid Internal FixationClinical Orthopaedics and Related Research, 1971