Outbreak of Legionnaires' disease associated with a supermarket mist machine
Authors:
Open Access
- 15 April 2010
- journal article
- research article
- Published by Cambridge University Press (CUP) in Epidemiology and Infection
- Vol. 138 (12) , 1823-1828
Abstract
SUMMARY: An outbreak of Legionnaires' disease affected 12 customers of a supermarket in a town in Catalonia, Spain, between August and November 2006. An epidemiological and environmental investigation was undertaken. Preliminary investigation showed that all patients had visited the same supermarket in this town where a mist machine was found in the fish section. Water samples were collected from the machine and from the supermarket's water distribution system when high-risk samples were excluded. Environmental samples from the mist machine and clinical samples from two patients tested positive for L. pneumophila serogroup 1 and had the same molecular pattern. The PFGE pattern detected in the clinical and mist-machine isolates had never previously been identified in Catalonia prior to the outbreak and has not been identified since. Four days after turning off the machine, new cases ceased appearing. Molecular study supports the hypothesis that the mist machine from the fish section of the supermarket was the source of infection. We believe it is essential to include exposure to mist machines in any legionellosis epidemiological survey.Keywords
This publication has 24 references indexed in Scilit:
- A community outbreak of Legionnaires’ disease associated with a cooling tower in Vic and Gurb, Catalonia (Spain) in 2005European Journal of Clinical Microbiology & Infectious Diseases, 2008
- Community‐AcquiredLegionellaPneumonia: New Insights from the German Competence Network for Community Acquired PneumoniaClinical Infectious Diseases, 2008
- Editorial Commentary:Community‐Acquired Legionnaires Disease: Implications for Underdiagnosis and Laboratory TestingClinical Infectious Diseases, 2008
- Genotypic variability and persistence of Legionella pneumophila PFGE patterns in 34 cooling towers from two different areasEnvironmental Microbiology, 2008
- Legionella pneumophila in Cooling Towers: Fluctuations in Counts, Determination of Genetic Variability by Pulsed-Field Gel Electrophoresis (PFGE), and Persistence of PFGE PatternsApplied and Environmental Microbiology, 2007
- A large Legionnaires' disease outbreak in Pamplona, Spain: early detection, rapid control and no case fatalityEpidemiology and Infection, 2007
- Clinical Study of an Outbreak of Legionnaire's Disease in Alcoy, Southeastern SpainEuropean Journal of Clinical Microbiology & Infectious Diseases, 2002
- Prospective Study of Community-Acquired Pneumonia of Bacterial Etiology in AdultsEuropean Journal of Clinical Microbiology & Infectious Diseases, 1999
- Communitywide Outbreak of Legionnaires' Disease Associated with a Grocery Store Mist MachineThe Journal of Infectious Diseases, 1992
- An Outbreak of Legionnaires' Disease Associated with a Contaminated Air-Conditioning Cooling TowerNew England Journal of Medicine, 1980