Purpose PET image quality is influenced by the patient size according to the current guideline. The study aimed to propose an optimized dose regimen to yield a constant image quality independent of patient habitus to meet the clinical needs. Methods A first patient cohort of 78 consecutive oncological patients (59.7 ± 13.7 years) who underwent a total-body PET/CT scan were retrospectively enrolled to develop the regimen. The patients were randomly distributed in four body mass index (BMI) groups according to the World Health Organization (WHO) criteria. The liver SNR (signal-to-noise ratio, SNRL) was obtained by manually drawing regions of interest (ROIs) and normalized (SNRnorm) by the product of injected activity and acquisition time. Fits of SNRnorm against different patient-dependent parameters were performed to determine the best correlating parameter and fit method. A qualitative assessment on image quality was performed using a 5-point Likert scale to determine the acceptable threshold of SNRL. Thus, an optimized regimen was proposed and validated by a second patient cohort consisted of prospectively enrolled 38 oncological patients. Results The linear fit showed SNRnorm had the strongest correlation (R2 = 0.69) with the BMI than other patient-dependent parameters and fit method. The qualitative assessment indicated a SNRL value of 14.0 as an acceptable threshold to achieve sufficient image quality. The optimized dose regimen was determined as a quadratic relation with BMI: injected activity (MBq) = 39.2 (MBq)/(− 0.03*BMI + 1.49)2. In the validation study, the SNRL no longer decreased with the increase of BMI. There was no significant difference of the image quality regarding the value of SNRL between different BMI groups (p > 0.05). In addition, the injected activity was reduced by 75.6 ± 2.9%, 72.1 ± 4.0%, 67.1 ± 4.4%, and 64.8 ± 3.5% compared with the first cohort for the four BMI groups, respectively. Conclusion The study proposed a quadratic relation between the 18F-FDG injected activity and the patient’s BMI for total-body 18F-FDG PET imaging. In this regimen, the image quality can maintain in a constant level independent of patient habitus and meet the clinical requirement with a reduced injected activity.Keywords
All Related Versions
This publication has 19 references indexed in Scilit:
- Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient CareJournal of Nuclear Medicine, 2017
- FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0European Journal of Nuclear Medicine and Molecular Imaging, 2014
- Optimum Lean Body Formulation for Correction of Standardized Uptake Value in PET ImagingJournal of Nuclear Medicine, 2014
- Impact of blood glucose, diabetes, insulin, and obesity on standardized uptake values in tumors and healthy organs on 18F-FDG PET/CTNuclear Medicine and Biology, 2013
- Optimized dose regimen for whole-body FDG-PET imagingEJNMMI Research, 2013
- Is Liver SUV Stable over Time in 18F-FDG PET Imaging?Journal of Nuclear Medicine Technology, 2011
- NEC Density and Liver ROI S/N Ratio for Image Quality Control of Whole-Body FDG-PET Scans: Comparison with Visual AssessmentMolecular Imaging and Biology, 2009
- Quantification of Lean BodyweightClinical Pharmacokinetics, 2005
- Proceedings of the 135th meeting of the Netherlands' Anatomical Society. Ghent, Belgium, October 11-12, 1985. Abstracts.1986
- Studies on the Constituents of Swertia japonica. III. : On the Flavonoid Constituents of the Plants of Swertia spp.YAKUGAKU ZASSHI, 1968