Removal of EOG Artifacts from EEG Recordings Using Stationary Subspace Analysis
Open Access
- 1 January 2014
- journal article
- research article
- Published by Wiley in The Scientific World Journal
- Vol. 2014, 1-9
Abstract
An effective approach is proposed in this paper to remove ocular artifacts from the raw EEG recording. The proposed approach first conducts the blind source separation on the raw EEG recording by the stationary subspace analysis (SSA) algorithm. Unlike the classic blind source separation algorithms, SSA is explicitly tailored to the understanding of distribution changes, where both the mean and the covariance matrix are taken into account. In addition, neither independency nor uncorrelation is required among the sources by SSA. Thereby, it can concentrate artifacts in fewer components than the representative blind source separation methods. Next, the components that are determined to be related to the ocular artifacts are projected back to be subtracted from EEG signals, producing the clean EEG data eventually. The experimental results on both the artificially contaminated EEG data and real EEG data have demonstrated the effectiveness of the proposed method, in particular for the cases where limited number of electrodes are used for the recording, as well as when the artifact contaminated signal is highly nonstationary and the underlying sources cannot be assumed to be independent or uncorrelated.Keywords
Funding Information
- National Natural Science Foundation of China (61105048, 20110092120034, BK20130696, 6722000008)
- Ministry of Education of the People’s Republic of China (61105048, 20110092120034, BK20130696, 6722000008)
- Natural Science Foundation of Jiangsu Province (61105048, 20110092120034, BK20130696, 6722000008)
- Ministry of Human Resources and Social Security (61105048, 20110092120034, BK20130696, 6722000008)
This publication has 20 references indexed in Scilit:
- Real‐Time EEG‐Based Happiness Detection SystemThe Scientific World Journal, 2013
- REG-ICA: A hybrid methodology combining Blind Source Separation and regression techniques for the rejection of ocular artifactsBiomedical Signal Processing and Control, 2011
- ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal featuresPsychophysiology, 2011
- Finding Stationary Subspaces in Multivariate Time SeriesPhysical Review Letters, 2009
- On the blind source separation of human electroencephalogram by approximate joint diagonalization of second order statisticsClinical Neurophysiology, 2008
- Automated protocol for evaluation of electromagnetic component separation (APECS): Application of a framework for evaluating statistical methods of blink extraction from multichannel EEGClinical Neurophysiology, 2007
- Optimization of an independent component analysis approach for artifact identification and removal in magnetoencephalographic signalsClinical Neurophysiology, 2004
- EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysisJournal of Neuroscience Methods, 2004
- A blind source separation technique using second-order statisticsIEEE Transactions on Signal Processing, 1997
- Ocular artifacts in EEG and event-related potentials I: Scalp topographyBrain Topography, 1993