Ultrasonic circular cyclocoagulation prospective safety and effectiveness study
- 21 April 2021
- journal article
- research article
- Published by Springer Nature in International Ophthalmology
- Vol. 41 (9) , 3047-3055
Abstract
Purpose To evaluate the efficacy and safety of ultrasound cycloplasty procedures (UCP) in patients with uncontrolled glaucoma. Methods Prospective longitudinal study with UCP was performed by EyeOP1© probe with 8 s duration on 6 or 8 sectors, according to baseline intraocular pressure (IOP). Complete ophthalmic examination was performed pre- and post-operatively at 1st day, 1st week, 1st, 3rd, 6th, 9th and 12th months. UCP was repeated beyond 3rd month if IOP was > 21 mmHg, under maximum therapy, without major complications. Primary outcomes were complete (IOP reduction ≥ 20% or reduction in number of antiglaucomatous drugs and IOP ≥ 5 mmHg without occurrence of major complications) and qualified (IOP reduction ≥ 20% or reduction in number of antiglaucomatous drugs and IOP ≥ 5 mmHg) surgical success rates at 12 months. Secondary outcomes were mean IOP reduction, mean number of drugs reduction, rates of failure, number of repeated procedures, mean time to failure and occurrence of complications. Results Fourteen eyes of 13 patients (11 male) with advanced glaucoma (Hoddap classification) were included. Six were surgically naïve. Mean age was 68.29 ± 10.66 years. Four eyes were treated in 8 sectors (28.5%). Patients were followed for 12 months after first UCP procedure. Overall surgical success was achieved in 92.9% at 6 months and in 100% of cases at 12 months. Mean IOP significantly reduced from 28.50 ± 7.61 mmHg to 13.79 ± 6.97 at 1 month, 17.36 ± 8.58 at 3 months, 17.79 ± 6.29 at 6 months, 16.3 ± 4.6 at 9 months and to 15.23 ± 5.09 at 12 months (p < 0.01). Mean number of drugs reduced from 3.71 ± 0.61 to 2.43 ± 1.51 at 3 months, 2.86 ± 1.1 at 6 months, 2.64 ± 0.93 at 9 months and to 2.92 ± 0.86 at 12 months (p < 0.05). Major reversible complications included choroidal detachment in 2 (14.29%) and corneal edema in 1 eye (7.14%), without permanent visual acuity reduction. Minor reversible complications included anterior chamber reaction (92.25%), conjunctival hyperemia (71.43%) and superficial keratitis (57.4%). Four eyes (28.57%) had indication for repeating UCP, with mean period to failure of 8.1 ± 3.95 months. Conclusion UCP procedures are effective in reducing IOP in severe glaucoma. Its application and repetition seem to be a medium-long term acceptable alternative to cyclodestructive surgery. However, long-term efficacy and safety require yet further investigation.Keywords
This publication has 19 references indexed in Scilit:
- Uveo-scleral outflow pathways after ultrasonic cyclocoagulation in refractory glaucoma: an anterior segment optical coherence tomography and in vivo confocal studyBritish Journal of Ophthalmology, 2016
- Multicenter clinical trial of high‐intensity focused ultrasound treatment in glaucoma patients without previous filtering surgeryActa Ophthalmologica, 2015
- High-Intensity Focused Ultrasound Treatment in Refractory Glaucoma Patients: Results at 1 Year of Prospective Clinical StudyEuropean Journal of Ophthalmology, 2015
- Cyclocoagulation of the Ciliary Bodies by High-Intensity Focused Ultrasound: A 12-Month Multicenter StudyInvestigative Ophthalmology & Visual Science, 2015
- Noninvasive glaucoma procedures: Current options and future innovationsMiddle East African Journal of Ophthalmology, 2015
- Global Prevalence of Glaucoma and Projections of Glaucoma Burden through 2040Ophthalmology, 2014
- Short- and Long-Term Effects on the Ciliary Body and the Aqueous Outflow Pathways of High-Intensity Focused Ultrasound CyclocoagulationUltrasound in Medicine & Biology, 2014
- Treatment of refractory open-angle glaucoma using ultrasonic circular cyclocoagulation: a prospective case seriesCurrent Medical Research and Opinion, 2014
- Pathology of cyclodiode laser: a series of nine enucleated eyesBritish Journal of Ophthalmology, 2002
- Cyclophotocoagulation A report by the american academy of ophthalmologyOphthalmology, 2001