Ear-Canal Reflectance, Umbo Velocity, and Tympanometry in Normal-Hearing Adults
- 1 January 2012
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 33 (1) , 19-34
Abstract
Objective: This study compares measurements of ear-canal reflectance (ECR) to other objective measurements of middle ear function including audiometry, umbo velocity (VU), and tympanometry in a population of strictly defined normal-hearing ears. Design: Data were prospectively gathered from 58 ears of 29 normal-hearing subjects, 16 females and 13 males, aged 22 to 64 yr. Subjects met all of the following criteria to be considered as having normal hearing: (1) no history of significant middle ear disease; (2) no history of otologic surgery; (3) normal tympanic membrane on otoscopy; (4) pure-tone audiometric thresholds of 20 dB HL or better for 0.25 to 8 kHz; (5) air-bone gaps no greater than 15 dB at 0.25 kHz and 10 dB for 0.5 to 4 kHz; (6) normal, type-A peaked tympanograms; and (7) all subjects had two “normal” ears (as defined by these criteria). Measurements included pure-tone audiometry for 0.25 to 8 kHz, standard 226 Hz tympanometry, ECR for 0.2 to 6 kHz at 60 dB SPL using the Mimosa Acoustics HearID system, and umbo velocity (VU) for 0.3 to 6 kHz at 70 to 90 dB SPL using the HLV-1000 laser Doppler vibrometer (Polytec Inc). Results: Mean power reflectance (|ECR|2) was near 1.0 at 0.2 to 0.3 kHz, decreased to a broad minimum of 0.3 to 0.4 between 1 and 4 kHz, and then sharply increased to almost 0.8 by 6 kHz. The mean pressure reflectance phase angle (∠ECR) plotted on a linear frequency scale showed a group delay of approximately 0.1 msec for 0.2 to 6 kHz. Small significant differences were observed in |ECR|2 at the lowest frequencies between right and left ears and between males and females at 4 kHz. |ECR|2 decreased with age but reached significance only at 1 kHz. Our ECR measurements were generally similar to previous published reports. Highly significant negative correlations were found between |ECR|2 and VU for frequencies below 1 kHz. Significant correlations were also found between the tympanometrically determined peak total compliance and |ECR|2 and VU at frequencies below 1 kHz. The results suggest that middle ear compliance contributes significantly to the measured power reflectance and umbo velocity at frequencies below 1 kHz but not at higher frequencies. Conclusions: This study has established a database of objective measurements of middle ear function (ECR, umbo velocity, tympanometry) in a population of strictly defined normal-hearing ears. These data will promote our understanding of normal middle ear function and will serve as a control for comparison to similar measurements made in pathological ears.Keywords
This publication has 58 references indexed in Scilit:
- Comparison of Ear-Canal Reflectance and Umbo Velocity in Patients With Conductive Hearing Loss: A Preliminary StudyEar & Hearing, 2012
- Motion of the surface of the human tympanic membrane measured with stroboscopic holographyHearing Research, 2010
- A sum of simple and complex motions on the eardrum and manubrium in gerbilHearing Research, 2010
- Differential Intracochlear Sound Pressure Measurements in Normal Human Temporal BonesJournal of the Association for Research in Otolaryngology, 2008
- Wideband absorbance tympanometry using pressure sweeps: System development and results on adults with normal hearingThe Journal of the Acoustical Society of America, 2008
- Clinical Utility of Laser-Doppler Vibrometer Measurements in Live Normal and Pathologic Human EarsEar & Hearing, 2008
- Test-Retest Reliability of Wideband Reflectance Measures in Infants under Screening and Diagnostic Test ConditionsEar & Hearing, 2007
- Superior Semicircular Canal Dehiscence Mimicking Otosclerotic Hearing Loss2007
- Middle ear mechanics in normal, diseased and reconstructed earsThe Journal of Laryngology & Otology, 1998
- Ear-canal impedance and reflection coefficient in human infants and adultsThe Journal of the Acoustical Society of America, 1993