Feasibility of single‐shot multi‐level multi‐angle diffusion tensor imaging of the human cervical spinal cord at 7T
- 25 January 2018
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (3) , 947-957
Abstract
Purpose: Diffusion tensor imaging (DTI), which is frequently used to characterize microstructure impairments in many spinal cord diseases at clinical fields, may benefit from 7T investigations. Yet, it presents specific technical challenges, such as increased magnetic susceptibility‐induced image distortions.Methods: Eight healthy volunteers were scanned at 7T using a prototype diffusion multi‐slice multi‐angle (MSMA) single‐shot spin‐echo echo planar imaging (EPI) sequence developed to explore the whole cervical spinal cord while limiting the partial volume effects related to the cord curvature. To mitigate the increased susceptibility‐induced distortions encountered at 7T, a reverse phase‐encoding strategy was also used. Images acquired from C1‐to‐C7 were registered to the AMU40 template to automatically extract DTI metrics in gray matter/white matter regions of interest. Effects of inhomogeneities on the DTI metrics and repeatability of the measurements were also investigated. Lastly, a DTI acquisition with a 400‐µm in‐plane resolution was acquired on one volunteer to push forward 7T potentialities.Results: The MSMA sequence allowed accessing to high‐resolution axial diffusion images sampling the whole cord within a single acquisition. DTI metrics were found in agreement with literature at lower field, stable along a 50–120% relative variation range, with a mean inter‐scan coefficient of variation of 8%. The two‐‐fold spatial‐resolution increase of the additional DTI acquisition enabled main white matter tracts visualization on a single‐subject basis.Conclusion: Although C7‐level imaging needs some improvement, this preliminary study shows that transverse 7T DTI of the whole cervical spinal cord is feasible, laying the groundwork for improved multi‐parametric MR investigations and microstructure characterization of the spinal cord. Magn Reson Med 80:947–957, 2018. © 2018 International Society for Magnetic Resonance in Medicine.Keywords
Funding Information
- CNRS
- Instituts Carnot
This publication has 42 references indexed in Scilit:
- Diffusion Weighted Image Denoising Using Overcomplete Local PCAPLOS ONE, 2013
- Diffusion imaging in humans at 7T using readout‐segmented EPI and GRAPPAMagnetic Resonance in Medicine, 2010
- Efficient correction of inhomogeneous static magnetic field-induced distortion in Echo Planar ImagingNeuroImage, 2010
- High‐resolution diffusion tensor imaging with inner field‐of‐view EPIJournal of Magnetic Resonance Imaging, 2009
- High b‐value q‐space diffusion‐weighted MRI of the human cervical spinal cord in vivo: Feasibility and application to multiple sclerosisMagnetic Resonance in Medicine, 2008
- Diffusion Tensor MR Imaging of the Neurologically Intact Human Spinal CordAmerican Journal of Neuroradiology, 2008
- Symmetric diffeomorphic image registration with cross-correlation: Evaluating automated labeling of elderly and neurodegenerative brainMedical Image Analysis, 2008
- Applications of diffusion‐weighted and diffusion tensor MRI to white matter diseases – a reviewNMR in Biomedicine, 2002
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- ADC mapping of the human optic nerve: Increased resolution, coverage, and reliability with CSF‐suppressed ZOOM‐EPIMagnetic Resonance in Medicine, 2001