Accelerator-based epithermal neutron sources for boron neutron capture therapy of brain tumors
Authors:
- 1 March 2003
- journal article
- research article
- Published by Springer Nature in Journal of Neuro-Oncology
- Vol. 62 (1-2) , 19-31
Abstract
This paper reviews the development of low-energy light ion accelerator-based neutron sources (ABNSs) for the treatment of brain tumors through an intact scalp and skull using boron neutron capture therapy (BNCT). A major advantage of an ABNS for BNCT over reactor-based neutron sources is the potential for siting within a hospital. Consequently, light-ion accelerators that are injectors to larger machines in high-energy physics facilities are not considered. An ABNS for BNCT is composed of: (1) the accelerator hardware for producing a high current charged particle beam, (2) an appropriate neutron-producing target and target heat removal system (HRS), and (3) a moderator/reflector assembly to render the flux energy spectrum of neutrons produced in the target suitable for patient irradiation. As a consequence of the efforts of researchers throughout the world, progress has been made on the design, manufacture, and testing of these three major components. Although an ABNS facility has not yet been built that has optimally assembled these three components, the feasibility of clinically useful ABNSs has been clearly established. Both electrostatic and radio frequency linear accelerators of reasonable cost (∼$1.5 M) appear to be capable of producing charged particle beams, with combinations of accelerated particle energy (a few MeV) and beam currents (∼10 mA) that are suitable for a hospital-based ABNS for BNCT. The specific accelerator performance requirements depend upon the charged particle reaction by which neutrons are produced in the target and the clinical requirements for neutron field quality and intensity. The accelerator performance requirements are more demanding for beryllium than for lithium as a target. However, beryllium targets are more easily cooled. The accelerator performance requirements are also more demanding for greater neutron field quality and intensity. Target HRSs that are based on submerged-jet impingement and the use of microchannels have emerged as viable target cooling options. Neutron fields for reactor-based neutron sources provide an obvious basis of comparison for ABNS field quality. This paper compares Monte Carlo calculations of neutron field quality for an ABNS and an idealized standard reactor neutron field (ISRNF). The comparison shows that with lithium as a target, an ABNS can create a neutron field with a field quality that is significantly better (by a factor of ∼1.2, as judged by the relative biological effectiveness (RBE)-dose that can be delivered to a tumor at a depth of 6 cm) than that for the ISRNF. Also, for a beam current of 10 mA, the treatment time is calculated to be reasonable (∼30 min) for the boron concentrations that have been assumed.Keywords
This publication has 29 references indexed in Scilit:
- Modification of the University of Washington Neutron Radiotherapy Facility for optimization of neutron capture enhanced fast‐neutron therapyMedical Physics, 2000
- Design study on an accelerator-based facility for BNCT and low energy neutron sourceProgress in Nuclear Energy, 2000
- Toward a final design for the Birmingham boron neutron capture therapy neutron beamMedical Physics, 1999
- Design for an accelerator‐based orthogonal epithermal neutron beam for boron neutron capture therapyMedical Physics, 1999
- Development of a high‐power water cooled beryllium target for use in accelerator‐based boron neutron capture therapyMedical Physics, 1998
- Designing accelerator‐based epithermal neutron beams for boron neutron capture therapyMedical Physics, 1998
- The Argonne ACWL, a potential accelerator-based neutron source for BNCTNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1995
- Low Energy Accelerator-Based Neutron Sources for Neutron Capture Therapy1993
- Epithermal BNCT Neutron Beam Design for a Triga II Reactor1993
- CW operation of the fmit RFQ acceleratorNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1985