Self-measured home blood pressure in predicting ambulatory hypertension
Open Access
- 1 November 2004
- journal article
- Published by Oxford University Press (OUP) in American Journal of Hypertension
- Vol. 17 (11) , 1017-1022
Abstract
Physicians are commonly uncertain whether a person with office blood pressure (BP) around 140/90 mm Hg actually has hypertension. This is primarily because of BP variability. One approach is to perform self-measured home BP and determine if home BP is elevated. There is a general agreement that if home BP is ≥135/85 mm Hg, then antihypertensive therapy may be commenced. However, some persons with home BP below this cut-off will have ambulatory hypertension. We therefore prospectively study the role of home BP in predicting ambulatory hypertension in persons with stage 1 and borderline hypertension. We studied in a cross-sectional way home and ambulatory BP in a group of 48 patients with at least two elevated office BP readings. The group was free of antihypertensive drug therapy for at least 4 weeks and performed 7 days of standardized self-BP measurements at home. We examined the relationships of the three BP methods and also defined a threshold (using receiver operating curves) for home BP that captures 80% of ambulatory hypertensives (awake BP ≥135/85 mm Hg). Office systolic BP (145 ± 13 mm Hg) was significantly higher than awake (139 ± 12 mm Hg, P = .013) and home (132 ± 11 mm Hg, P < .001) BP. Office diastolic BP (88 ± 4 mm Hg) was higher than home diastolic BP (80 ± 8 mm Hg, P < .001) but not different from awake diastolic BP (88 ± 8 mm Hg, P = .10). Home BP had a higher correlation (compared with office BP) with ambulatory BP. The home BP-based white coat effect correlated with ambulatory BP-based white coat effect (r = 0.83, P = .001 for systolic BP; r = 0.68, P = .001 for diastolic BP). The threshold for home BP of 80% sensitivity in capturing ambulatory hypertension was 125/76 mm Hg. Our preliminary data suggest that a lower self-monitored home BP threshold should be used (to exclude ambulatory hypertension) in patients with borderline office hypertension.Keywords
This publication has 8 references indexed in Scilit:
- Accuracy of telemedical home blood pressure measurement in the diagnosis of hypertensionJournal of Human Hypertension, 2003
- Value of Home Blood Pressures as Predictor of Target Organ Damage in Mild Arterial HypertensionEuropean Journal of Preventive Cardiology, 2002
- Relationship between Home Blood Pressure and Longitudinal Changes in Target Organ Damage in Treated Hypertensive PatientsHypertension Research, 2002
- Normal values of blood pressure self-measurement in view of the 1999 World Health Organization-International Society of Hypertension guidelinesAmerican Journal of Hypertension, 2000
- Validation of A&D UA-767 device for the self-measurement of blood pressureBlood Pressure Monitoring, 2000
- The relationship of electronically monitored physical activity to blood pressure, heart rate, and the circadian blood pressure profileAmerican Journal of Hypertension, 2000
- Multiple Clinic and Home Blood Pressure Measurements Versus Ambulatory Blood Pressure MonitoringHypertension, 1999
- Multicenter Assessment of the QuietTrak Ambulatory Blood Pressure Recorder According to the 1992 AAMI GuidelinesAmerican Journal of Hypertension, 1994