Inter‐zonal airflows within multi‐unit residential buildings (MURBs) have profound impacts on an array of building performance metrics, including energy, indoor air quality (IAQ), fire and acoustical separations and distribution of ventilation air. Although there are wide‐ranging implications, most building codes/standards have yet to incorporate airtightness requirements for interior partitions in large, multi‐zone structures, and instead focus primarily on exterior envelope airtightness. Despite the multi‐disciplinary nature of the topic, previous reviews have been limited to one domain (e.g., energy performance, IAQ, specific test methods, etc.). This paper presents a comprehensive summary of the literature on inter‐zonal airflow in MURBs including the magnitude and interaction of driving forces; its relevance to/effect on building performance; current code requirements; testing methods; and previous measurements. While considerable efforts have been made in recent years to quantify and control inter‐zonal airflows, most measurement techniques are still labour‐intensive and disruptive, and there is no framework for how to implement performance‐based requirements into building codes and standards. Further research efforts should be focused on refining testing methods and preparing the construction industry for code changes.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada (RGPIN‐2016‐06234)
This publication has 93 references indexed in Scilit:
- Air-Infiltration Measurements in Buildings Using Sound Transmission Loss Through Small AperturesInternational Journal of Green Energy, 2013
- Stack Pressure and Airflow Movement in High and Medium Rise buildingsEnergy Procedia, 2011
- Secondhand Smoke Transfer in Multiunit HousingNicotine & Tobacco Research, 2010
- Evaluation on indoor environment quality of dense urban residential buildingsJournal of Facilities Management, 2008
- Wind-induced internal pressure fluctuations of structure with single windward openingJournal of Zhejiang University-SCIENCE A, 2006
- Penetration coefficient and deposition rate as a function of particle size in non-smoking naturally ventilated residencesAtmospheric Environment, 2003
- Evaluating the Air Pressure Response of Multizonal BuildingsJournal of Thermal Envelope and Building Science, 2002
- Energy Saving and Airtightness of Blocks of Flats in LithuaniaIndoor and Built Environment, 2000
- Minimizing pest risk in dwellingsStructural Survey, 1996
- Sound Insulation in BuildingsJournal (Royal Society of Health), 1959