Intravascular Ultrasound Results From the NEVO ResElution-I Trial
Authors:
- Yasuhiro HondaYasuhiro Honda
- Brian K. CourtneyBCBrian K. Courtney
- Takao ShimohamaTSTakao Shimohama
- Junya AkoJAJunya Ako
- Katsuhisa WasedaKWKatsuhisa Waseda
- Nathalie MacoursNMNathalie Macours
- Campbell RogersCRCampbell Rogers
- Jeffrey J. PopmaJPJeffrey J. Popma
- Alexandre AbizaidAAAlexandre Abizaid
- John A. OrmistonJOJohn A. Ormiston
- Christian SpauldingCSChristian Spaulding
Open Access
- 1 April 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 4 (2) , 146-154
Abstract
Background—: The NEVO sirolimus-eluting stent (NEVO SES) is a novel cobalt-chromium stent combining sirolimus release from reservoirs with bioabsorbable polymer to reduce spatial and temporal polymer exposure. The aim of this study was to assess the arterial response to the NEVO SES in a randomized, blinded comparison versus the surface-coated TAXUS Liberte paclitaxel-eluting stent (TAXUS Liberté PES) in human native coronary lesions using intravascular ultrasound (IVUS). Methods and Results—: The NEVO ResElution-I IVUS substudy enrolled 100 patients (1:1 randomization). In addition to standard IVUS variables, uniformity of neointimal distribution within stents was evaluated in 3 dimensions by computing mean neointimal thickness within 12 equally spaced radial sectors on every 1-mm cross section along the stented segment. The NEVO SES showed significantly less neointimal proliferation (neointimal obstruction: 5.5±11.0% versus 11.5±9.7%, P =0.02), resulting in less late lumen area loss and smaller maximum cross-sectional narrowing at 6 months. The absolute variability of neointima distribution, assessed by the standard deviation of neointimal thickness within each stent, was significantly reduced with the NEVO SES compared with the TAXUS Liberté PES(0.04±0.04 mm versus 0.10±0.07 mm, P 3 /mm versus 0.36±0.63 mm 3 /mm, respectively, P =0.003). Conclusions—: The NEVO SES with focal release of sirolimus from reservoirs achieved significantly greater and more consistent suppression of neointimal hyperplasia than the surface-coated TAXUS Liberté PES. This was associated with less positive remodeling and no increased morphological or morphometric abnormalities surrounding the stent or at the stent margins. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00714883.Keywords
This publication has 25 references indexed in Scilit:
- Six-Month Results of the NEVO RES-ELUTION I (NEVO RES-I) TrialCirculation: Cardiovascular Interventions, 2010
- Heterogeneous Arterial Healing in Patients Following Paclitaxel-Eluting Stent ImplantationJACC: Cardiovascular Interventions, 2009
- Drug-Eluting Stents Insights From Invasive Imaging TechnologiesCirculation Journal, 2009
- Clinical End Points in Coronary Stent TrialsCirculation, 2007
- Sirolimus and Paclitaxel on Polymer-Based Drug-Eluting StentsJACC, 2006
- Sirolimus-Eluting Stents Associated With Paradoxic Coronary VasoconstrictionJACC, 2005
- Polymer-based paclitaxel-eluting stents reduce in-stent neointimal tissue proliferationJACC, 2005
- Sirolimus-Eluting Stents versus Standard Stents in Patients with Stenosis in a Native Coronary ArteryNew England Journal of Medicine, 2003
- Preliminary Observations Regarding Angiographic Pattern of Restenosis After Rapamycin-Eluting Stent ImplantationCirculation, 2003
- 7-Hexanoyltaxol–Eluting Stent for Prevention of Neointimal GrowthCirculation, 2002