A Generalized Instantaneous Method for Harmonics, Positive and Negative Sequence Detection/Extraction
- 1 January 2007
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 02759306,p. 2294-2297
Abstract
One of the most common problems in power systems is the unbalanced load and harmonics that causes losses and interference in power systems. To eliminate or detect these problems, the compensator or detection equipment needs an algorithm for the real time detection/extraction of the positive, negative sequence and harmonics components that will be used for generating the reference signal for the converter or analyzer. This paper proposes a generic method to obtain the positive, negative and/or harmonics reference signals that not requires any coordinate transform or signal filtering.Keywords
This publication has 20 references indexed in Scilit:
- A new instantaneous method for harmonics, positive and negative sequence detection for compensation of distorted currents with static converters using pulse width modulation2005
- The p-q theory for active filter control: some problems and solutionsSba: Controle & Automação Sociedade Brasileira de Automatica, 2004
- Calculating approach and implementation for active filters in unbalanced three-phase system using synchronous detection method2003
- A comparison of active power filter control methods in unbalanced and non-sinusoidal conditions2002
- Instantaneous power compensation in three-phase systems by using p-q-r theory2002
- Statcom controls for operation with unbalanced voltagesIEEE Transactions on Power Delivery, 1998
- Control system for three-phase active power filter which simultaneously compensates power factor and unbalanced loadsIEEE Transactions on Industrial Electronics, 1995
- Using phasors to analyze power system negative phase sequence voltages caused by unbalanced loadsIEEE Transactions on Power Systems, 1994
- Current compensation in three‐phase power systemsEuropean Transactions on Electrical Power, 1993
- Power factor improvement of three‐phase unbalanced loads with non‐sinusoidal supply voltageEuropean Transactions on Electrical Power, 1993