Performance of an Efficient Hybrid Dilated–Long Short-Term Memory with Residual Learning for High-Fidelity Electrocardiogram Denoising Signal
Open Access
- 22 July 2026
- journal article
- research article
- Published by MDPI AG in Technologies
- Vol. 14 (7) , 453
Abstract
Addressing the critical challenge of signal degradation in biosensor cardiac monitoring, this paper introduces an efficient hybrid dilated–long short-term memory (LSTM) with residual learning (HDLR), which is a novel architecture engineered for a high-fidelity electrocardiogram (ECG) denoising signal. The proposed HDLR model synergistically integrates with dilated convolutions to expand the receptive field for multi-scale feature extraction. This is an LSTM-based backbone used to resolve long term temporal dependencies with residual learning paths to stabilize gradient flow and accelerate convergence. The proposed HDLR architecture integrates three core functional components with dilated convolutional layers utilized for local temporal feature extraction, where varying dilation rates expand the receptive field to capture both local waveform patterns and broader morphological structures without increasing computational complexity. Experimental results demonstrate a significant leap in performance, with the HDLR model achieving a mean squared error (MSE) of 0.002176, a signal-to-noise ratio (SNR) of 14.4420 dB, and a Matthews correlation coefficient (MCC) of 0.9822. Beyond quantitative metrics, the proposed HDLR architecture exhibits exceptional robustness in preserving cardiac morphology, specifically the P-wave and QRS complex of the ECG signal under stochastic noise conditions. These findings underscore the HDLR model’s potential as a backbone for next generation, real time diagnostic systems in intelligent healthcare.Keywords
This publication has 21 references indexed in Scilit:
- Exploring a Novel Conv‐Transformer Network for Multi‐Modality Heart SegmentationiRADIOLOGY, 2025
- A proposed deep learning model for multichannel ECG noise reductionDiscover Artificial Intelligence, 2025
- A novel framework for sentiment classification employing Bi-GRU optimized by enhanced human evolutionary optimization algorithmScientific Reports, 2025
- Enhancing wind power forecasting accuracy through LSTM with adaptive wind speed calibration (C-LSTM)Scientific Reports, 2025
- ECG Classification Exercise Health Analysis Algorithm Based on GRU and Convolutional Neural NetworkIEEE Access, 2024
- A Deep Bidirectional GRU Network Model for Biometric Electrocardiogram Classification Based on Recurrent Neural NetworksIEEE Access, 2019
- Abnormalities State Detection from P-Wave, QRS Complex, and T-Wave in Noisy ECGJournal of Physics: Conference Series, 2019
- Noise Reduction in ECG Signals Using Fully Convolutional Denoising AutoencodersIEEE Access, 2019
- Feature saliency using signal-to-noise ratios in automated diagnostic systems developed for ECG beatsExpert Systems with Applications, 2005
- The impact of the MIT-BIH Arrhythmia DatabaseIEEE Engineering in Medicine and Biology Magazine, 2001